ABSTRACT A new electronic design for continuous motional series resonant frequency monitoring of loaded quartz crystal resonators is presented. Using this circuit, a low-cost method for a simple determination of equivalent circuit parameters of quartz crystal resonators is described. Measurements made with the proposed system on typical AT cut quartz crystals are in good agreement with those of an Impedance Analyzer.
© 2001, by The Institute of Electrical and Electronics Engineers, Inc. All rights reserved.