IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS. AND FREQUENCY CONTROL. VOL. 39. NO. 3. MAY 1991
Hysteresis in Quartz Resonators-A Review
John A. Kusters, Senior Member, IEEE, and John R. Vig, Fellow, IEEE
Manuscript received September 5. 1990: revised November 2.
19W accepted November 9. 1990.
Abstract
-The frequency versus temperature and pressure versus temperature characteristics of quartz crystal resonators do not repeat exactly upon temperature cycling, i.e., resonators exhibit "hysteresis." The subject of hysteresis is reviewed. The subject has been studied only sporadically until recently. A search of the literature has revealed only about a dozen papers in the Proceedings of the Annual Symposium on Frequency Control, a couple of contract reports, and a few other papers that deal with the subject. Books dealing with oscillators either do not mention the subject at all, or devote only a few sentences to the phenomenon. The causes of hysteresis are not well understood. The evidence to date is inconclusive. The mechanisms that can cause hysteresis include: strain changes, changes in the quartz, contamination redistribution, oscillator circuitry hysteresis, and apparent hysteresis due to thermal gradients.INTRODUCTION
With the advent of the microcomputer compensated crystal
oscillator (MCXO), thermal hysteresis has become the dominant factor limiting the
stability achievable with temperature compensated oscillators. Since the next largest
limiting factor is orders of magnitude smaller than hysteresis, future improvements in
MCXO stability depend primarily on reducing the hysteresis. Similarly, as sensor
technology has improved, hysteresis has become a limiting factor in the accuracies
achievable with quartz resonator sensors.
The purpose of this paper is to review the subject of hysteresis. The
subject has been studied only sporadically until recently. A search of the literature has
revealed only about a dozen papers in the Proceedings of the Annual Symposium on
Frequency Control [1]-[6], [9],
[11]-[15] a couple of Army contract reports, [16], [18] and a few other papers [19]-[23] that deal with the subject. Books dealing with oscillators either do
not mention the subject at all, or devote only a few sentences to the phenomenon.
An ideal quartz crystal resonator's frequency versus temperature
characteristic can be described by a single valued function. Frequency can then be
uniquely determined from knowing the temperature. In "real-world' , resonators,
however, the frequency versus temperature characteristic does not repeat exactly upon
temperature cycling.
The lack of frequency versus temperature (f versus T)
repeatability has been referred to at various times as "retrace,"
"hysteresis," "restart," and "thermal memory. " No formal
definitions existed before the advent of MIL-0-553 1013, 1 the
military specification for crystal oscillators. [24] MIL-0-55310B
defines "retrace" and "hysteresis." It distinguishes between the two
terms by defining "retrace" as the nonrepeatability of the f versus T
characteristic, at a fixed temperature, upon on-off cycling an oscillator under specified
conditions, and "hysteresis" as the maximum value of the nonrepeatability in the
f versus T characteristics during a temperature cycle, i.e., as the
difference between the up-cycle and the downcycle f versus T characteristics
at the temperature where that difference is maximum. Although the complete f versus
T loop may be called the "hysteresis characteristic" of an oscillator, in
order to quantify the phenomenon for specification purposes, the worst-case hysteresis is
defined as the "hysteresis" in MIL-0-55310. Hysteresis is determined during a
complete quasistatic temperature cycle between the specified temperature limits.
"Quasistatic" means that the temperature is changed in such a manner as to
ensure that-the frequency offsets due to thermal gradients are much smaller than the
specified f versus T stability, including hysteresis.
"Retrace" is usually applied to specifying oven controlled
crystal oscillators (OCXO), whereas "hysteresis" is usually applied to
specifying temperature compensated crystal oscillators (TCXO). Fig. 1
illustrates TCXO hysteresis: Fig. 2 illustrates OCXO retrace.
Fig. 1. TCXO thermal hysteresis Fig. 2. OCXO retrace.
A REVIEW OF THE LITERATURE
The following summarizes the literature on hysteresis. Included are three papers
that deal with frequency versus pressure hysteresis, as these may possibly have relevance
to frequency versus temperature hysteresis.
Early researchers who studied the stabilization and startup of
precision ovenized resonators noted that, when the oven was turned off after stabilization
and turned on at a later time, the frequency after restabilization at the original
temperature was slightly different from the resonator's frequency just before oven
shutdown, [25] as is illustrated in Fig. 2.
According to Sykes, [26] et al.. "This frequency shift has been
attributed to sorption of minute quantities of gas on the crystal surface during an oven
or oscillator shutdown. " Also recognized as sources of instabilities during
stabilization were "relaxation of strain, or defects in the quartz itself. "
The Union Thermoelectric Handbook [16] mentioned
hysteresis as follows: "Temperature changes can result in mechanical changes within
the unit. For example, the mounting supports and bonding material may be altered more or
less permanently by a change in temperature, resulting in a difference in the stress
applied to the quartz plate. Some of the apparent hysteresis phenomenon [sic] have this
origin. "
Hammond et al. reported the first (and, until recently, the
only) in-depth studies of hysteresis. [1], [19], [20] Their research was aimed at improving the performance of an LC-cut
resonator that had been developed for a quartz thermometer. Although the resonators were
cycled over various temperature ranges between +2500C and -2000C,
the "hysteresis" was reported as the frequency shift at O'C only (due to the
high temperature coefficient of the LC-cut and the difficulty of obtaining accurate
enough temperature measurements at other temperatures.) Fig. 3 shows
the hysteresis of an LC-cut.
Fig. 3. Typical hysteresis curve.
Hammond et al. observed that: 1) the fundamental mode
and third overtone c-modes exhibited nearly identical hysteresis, while the fundamental b-
and a-modes exhibited a smaller hysteresis than the c-modes; 2) identically fabricated AT-cuts
showed a five times smaller hysteresis than the LC-cuts and the hysteresis of the AT-cut
was of opposite sign; 3) there was no systematic variation of hysteresis with electrode
material or electrode thickness-the electrodes tried included both higher- and
lower-than-quartz thermal expansion coefficient materials, and ductile as well as stiff
materials; 4) there was no systematic variation of hysteresis with mounting type,
stiffness, and rotation of the mounting orientation by 900, or with the
amplitude-of-vibration distribution; beveled plano-plano fundamental-mode
resonators, contoured fundamental-mode resonators and third overtone resonators showed the
same hysteresis; 5) there was no systematic variation of hysteresis with quartz type or
concentration of defects-natural quartz, cultured quartz, optical grade cultured quartz,
and swept quartz were tried; 6) there was no correlation with X-ray induced frequency
changes; 7) there was a systematic variation of hysteresis with angle of cut in rotated Y-cuts-a
change of sign of the hysteresis effect was found at q = 320;
and 8) although contamination in the resonator enclosure could aggravate the hysteresis,
when proper contamination control measures were applied during processing, the remaining
hysteresis was not related to contamination.
Hammond et al. [1] concluded that "all
the experiments to date indicate that the hysteresis effect in the quartz thermometer must
be a property of crystalline quartz. However, it is not clear whether it is an intrinsic
property of quartz or attributable to a defect structure. The variability from resonator
to resonator and from observation to observation would infer a defect structure." In
a slightly later paper, [ 19] however, the authors state that
hysteresis is "related to the differential expansion between the quartz plate and the
thin film, as well as micro contamination [sic] within the crystal holder. "
In 1970, Dick and Silver [2] showed the result for a
single fundamental-mode 5-MHz crystal, the f versus T characteristic of
which repeated to 3 X 10-8 for one cycle between -400C and +800C.
Buroker and Frerking [3] developed a digitally
compensated TCXO the f versus T stability of which was ±5 x 10-8
from -400C to +800C. In the conclusion of their report, however,
they stated that, the "technique is capable of even greater stabilities, but even ±5
X 10-8 cannot be maintained in practical environments due to thermal hysteresis
in crystals and other components."
Mroch and Hykes [4], [17]
evaluated a variety of purchased 4.5-MHz fundamental-mode AT-cut crystal units in
connection with the development of a high stability TCXO. They found that the retrace at
the lower turnover point varied from 3 ppm to less than 1 X 10-9, "with no
correlation from lot to lot or vendor," and that ".. few of the crystals
received met the ±3 X 10-8 retrace [sic] requirement" of the research
program. They also found that the hysteresis was "dependent on the highest
temperature to which the crystal had been recently exposed," it was maximum at the
low temperature limit of the temperature cycle, as is illustrated in Fig.
4, and, after 30min exposures to 1000C, hysteresis was a function of
storage time at room temperature. The ceramic capacitors used as bypass capacitors were
identified as potential sources of TCXO hysteresis.
Fig. 4. Hysteresis effects in the frequency-temperature characteristic of 4-MHz TCXO
Forster [5] measured the hysteresis of AT- and SC-cut
10-MHz third-overtone crystal units in HC-27/U glass enclosures, "from three German
manufacturers." He found that "With nearly all the test specimens it is striking
that quite large hysteresis values are obtained in the first cycle. The reproducibilities
of the second and third cycles is in general excellent ... namely ± 1 X 10-8.
In the first up run a 'calming phase' evidently sets in." He concluded that the
hysteresis of ". . . SC-cut crystals measured were not vastly superior to
those of AT-cut specimens," and that "The frequency stability attainable
with digitally temperature-compensated quartz crystal oscillators is limited to around ...
±1 X 10-7 solely by the thermal hysteresis of the
crystal resonators."
Vig et al. [6] measured nine ceramic flatpack
enclosed four-point-mounted SC-cut crystal units and two similarly fabricated AT-cut
control units, then compared the hysteresis at the lower turnover temperatures. The
worst-case hysteresis of the SC-cut units was 8.5 X 10-8. The AT-cuts
were about 10 times worse. The hysteresis was measured during two complete cycles between
-450C and +750C.
Kaitz [7] and Kusters and Kaitz [8]
studied the frequency versus pressure hysteresis of BT-cut pressure transducer
resonators. Kaitz found that "Hysteresis ... increases considerably as temperature
and pressure are increased," and "extensively cycling" the transducers,
which -relaxes the residual stresses incurred during processing of the unit,"
improved hysteresis "in almost all instances ... up to 50%." Kusters and Kaitz
found a correlation between pressure hysteresis and the quartz material, and between the
temperature of worst pressure hysteresis and the quartz material. Unswept natural quartz
showed the lowest hysteresis. Sweeping natural quartz increased the hysteresis. Pure
Z-growth material showed a hysteresis similar to that of swept natural quartz. The highest
hysteresis was found when X-growth material was used. Anomalously high hysteresis in some
"X-growth" transducers was traced to the fact that the transducers "were
found to contain regions of Z-growth material and clearly defined X-Z growth boundaries.
" No correlation was found between inclusion density and hysteresis.
Ueda et al. [9] reported that when a tuning
fork thermometer resonator was made relatively stress free by making a "narrow neck
between the resonator support and vibrating beams to further reduce the stress transmitted
from the support to the vibrating beams . . . " the hysteresis, when cycled between
4.20K and O0C, was reduced by a factor of two at 4.20K
and a factor of three at O0C, when compared to the conventional tuning fork,
and, at O0C, it was "one tenth that of thickness shear-mode resonator.
" No details are provided with respect to the number of units tested or the type of
thickness shear resonator that was used for the comparison.
Tuladhar et al. [21] studied the hysteresis
of 5- and 10MHz AT-cut resonators with gold electrodes and with silver electrodes.
Their conclusions were that: "Hysteresis at the lower turn-over-temperature is higher
than that at the upper turn-over-temperature ... Hysteresis for gold electroded crystals
is considerably worse than that for silver electroded crystals ... Crystals having a
double adjusting layer show greater hysteresis than those with a single layer.
Ward and EerNisse [10] found a correlation between
pressure hysteresis and quartz material, as did Kusters and Kaitz. Transducers made of
pure Z-growth cultured quartz exhibited higher hysteresis than those made from natural
quartz.
Tartakovskii [22] analyzed the results of Hammond
et al. and of U.S.S.R. researchers Varfolomeeva et al. (reference [2]
of Tartakovskii [22]). He states that ". . . by taking into
account the two different manifestations of thermal inertia in a piezoelectric element it
is possible to explain all experimental results" of Hammond et al. One
manifestation of "thermal inertia" is "the lag of the average temperature
Tp in the piezoelectric element behind that of the medium TM,, by D T1, " and the other is
the "difference D T2 in temperatures at the edge and the center of a piezoelectric element
creates in the central region of the plate compressive stresses . . . " which produce
a frequency shift that is a function of the plate's angles of cut and mounting
orientation. He also explains the AT-cut hysteresis results of Varfolomeeva et
al. by showing that the results are consistent with frequency changes to be expected
from "a change of the mechanical stresses in the ring of silver paste" that was
used to bond the mounting clips to the quartz plate. His "calculated results showed
why a simple turn in the direction of the ring towards the axis Z' (i.e., a shift
from y = 450 to y = 750)
caused a sharp reduction of frequency hysteresis following a temperature treatment . .
."
Beaussier [23] drew a similarity between mechanical
hysteresis and thermal hysteresis and concluded that "the phenomenon of nonlinear
elasticity in the presence of crystalline faults, and in particular moving dislocations
appear to be the cause." He further reported that continued thermal cycling, after
proper selection of the quartz itself, reduces thermal hysteresis to some limiting value.
Beaussier described a model that explained the experimental data where: hysteresis - KH(D T)2
where KH is between 0.5 X 10-10/0C2
and 1.1 X 10-10/0C2 for SC-cuts, and between 1.0 X
10-10/ 0 C2 and 1. 5 X 10-10
/ 0C2 for AT-cuts, and where AT is
the maximum temperature excursion during the up and down temperature cycles.
Filler [11] analyzed TCXO thermal hysteresis and
showed that thermal lag between the resonator and the TCXO's thermometer is a major
contributor to the observed TCXO hysteresis. He developed a model "that accounts for
both the normally encountered and anomalous thermal hysteresis. This model can separate
apparent hysteresis from 'true hysteresis'." He showed that "the inherent
hysteresis of the resonator is much lower than that of the TCXO and has a different
temperature dependence," and that "thermal hysteresis is independent of rate of
change of temperature, when thermal lag is accounted for . . . "
Symonds and Wacker [18] encountered excessive f versus
T hysteresis during the initial stages of a TCXO development program. They
attempted to vary the design and fabrication of the (10-MHz fundamental -mode AT-cut)
resonators in order to reduce the hysteresis. The results to date indicate that the
resonator's mounting plays an important role in the observed hysteresis. When the
stiffness of the mounting clips and the bonding areas of four-point mounted resonators
were reduced significantly, the average hysteresis was reduced from 0.64 ± 0.35 ppm to
0.20 + 0.07 ppm.
Filler and Vig [12] developed dual-mode SC-cut
resonators for microcomputer compensated crystal oscillators (MCXO). They, together with
Schodowski, [13] showed that when the dual-mode self-temperature
sensing method [13] is used as the "thermometer" during f
versus T measurements, the effects of thermal gradients can be made negligible
even when the temperature is changed rapidly. In the self-temperature sensing method, the
fundamental mode and third overtone c-mode frequencies are excited simultaneously. The
frequencies of these c-modes are measured versus a thermometric beat frequency that is
derived from the two c-modes. The resonator acts as its own thermometer; no external
thermometer is needed.
Filler and Vig applied the dual-mode self-temperature sensing method to
measuring the hysteresis of 10MHz/ 3.3-MHz dual-mode SC-cut resonators in a - 550C
and + 850C temperature range. "The measured hysteresis ranged from parts
in 109 for the best units, to about 2 X 10-8
for the typical 'good' unit, to several parts in 108 for the 'bad' units."
Filler [14] continued these hysteresis studies and showed that for
10-MHz third-overtone SC-cut resonators obtained from four manufacturers: 1)
hysteresis varies with temperature excursion, but for a given temperature cycle, the
hysteresis repeats, 2) hysteresis is not always worse at low temperatures, 3) resonator
manufacturing lots exhibit "signatures," i.e., resonators within a lot showed
similar hysteresis characteristics, but the characteristics varied significantly
from lot to lot, and 4) a factor of two change in drive current did not affect the
hysteresis.
Filler, Messina and Rosati [15] studied the
performance, including hysteresis, of microcomputer compensated crystal oscillators (MCXO)
that used dual-mode SC-cut resonators similar to those developed by Filler and Vig.
[12] Hysteresis of the seven MCXO's evaluated ranged from ±5 X 10-9 to ±4 X 10-8.
Benjaminson [27] investigated circuit contributions
to oscillator hysteresis. He analyzed the effects of hysteresis in the most critical
components of a dual-mode crystal oscillator (for use in a MCXO). One oscillator of the
pair was a 10-MHz third-overtone bridge oscillator, the other a 3.4-MHz fundamental-mode
impedance- inverting Colpitts oscillator. He found that a 1 % change in the tuned circuit
inductance of the bridge oscillator changed the frequency of oscillation by 1 X 10-8,
while a similar variation in the PI-network inductance of the Colpitts oscillator caused a
change of 7 X 10-8. Since both oscillators are series resonant circuits,
additional tests were performed in order to isolate the effects of circuit component
hysteresis from crystal hysteresis, by replacing the crystal with fixed resistors in each
oscillator, enabling operation as LC oscillators at the nominal operating
frequencies.
Hysteresis measured during cycling between -550C and +850C
was typically less than 50 ppm, which translated to a contribution less than 1 X 10-10 of versus T hysteresis in the 10-MHz
oscillator (when operating as a crystal oscillator) and less than 6 X 10-10
hysteresis in the 3.4-MHz crystal oscillator.
The low hysteresis effects demonstrated by the LC components
were achieved by careful analysis to select the most stable inductors and capacitors
available and equally careful circuit analysis to minimize frequency pulling by the
reactances. To accomplish this, the bridge oscillator was designed with as wide an LC
bandwidth as b-mode rejection permitted; b-mode traps per se, were avoided because their
pulling effects are much worse.
The impedance-inverting Colpitts oscillator was designed with the
lowest possible reactance values. This was limited by restrictions on transistor current
consumption. Higher current operation can provide higher transconductance, permitting
lower reactance with a consequent reduction in frequency pulling. An added benefit,
particularly in the low resistance fundamental-mode oscillator, was produced by the lower
equivalent series resistance of small, high Q inductors that reduce loaded Q degradation
and further minimize pulling due to reactance changes.
HYSTERESIS MECHANISMS
So what causes hysteresis? Since the evidence reported to date is inconclusive, we will
discuss the various mechanisms that can possibly cause the phenomenon.
Contamination Redistribution: Adsorption-desorption phenomena
can cause hysteresis if, during temperature cycling, contamination inside the resonator
enclosure is redistributed so as to change the mass loading on the active area of the
resonator. Sykes et al. [28] stated that "A study of the
stabilization characteristics of precision oscillators following interruptions of
oscillation lead to the conclusion that residual contamination within the crystal unit
enclosure is the most likely cause of frequency change during the first several days of
operation after an interruption. " Armstrong et al. [29]
showed that the retrace of "clean" 5-MHz thermocompression-bonded,
high-temperature processed resonators was superior to that of similar but solder-bonded
resonators. Hammond et al. [1] stated that "with inadequate
vacuum baking or inadequate cleaning of the crystal mounts, header, or can, the hysteresis
effect can be aggravated. However, . . . the remaining hysteresis effects are not related
to contamination. "
When one examines precision resonators' hysteresis curves, it is
difficult to see evidence that contamination transfer is a significant factor. Desorption
rates generally have an exponential dependence on temperature. Therefore, if
adsorption-desorption phenomena played a major role, then hysteresis would show a strong
temperature dependence, which has not been reported. When surfaces are heated to produce a
uniformly rising temperature, desorption (of a single adsorbent) occurs in a narrow
temperature interval, with a pronounced peak [30]. The temperature of
maximum desorption rate is a function of desorption energy, and is often used to
investigate the interaction of gases with metal surfaces. The characteristic
"moisture dip" observed when resonator enclosures contain water vapor is a
manifestation of adsorption and desorption occurring in a narrow temperature range. In
order for contamination transfer to explain the observed hysteresis, a variety of
contaminant molecules, with an appropriate range of adsorption energies, would need to be
present in the resonator enclosure.
Ideally, in order to eliminate adsorption-desorption as a hysteresis
mechanism, the electrodes should either be highly active or inert. In the first case, all
the contamination would be permanently adsorbed (i.e., the contaminant's lifetime on the
surface would be infinite). In the second case, none of it would be adsorbed (i.e., the
contaminants' lifetime would be zero). In real resonators, however, the contaminants'
lifetimes on surfaces are finite. The lifetimes depend on the surfaces, contaminant
molecules and temperatures.
Hysteresis in isothermal adsorption-desorption (as a function of gas
pressure) has been reported, e.g., during the adsorption and desorption of water on the
gold electrodes of quartz crystal resonators [31]. Such hysteresis,
being a small perturbation of a small effect, is probably a negligible second-order effect
in f versus T hysteresis.
Strain Changes: It is well known that changes in the stresses on a
resonator plate can produce frequency shifts. The stresses experienced by resonators
include mounting stresses (via the force-frequency effect [32], [33] and bending effects [34], bonding stresses, [35] and electrode stresses [36]. It is clear that
temperature cycling can produce changes in these stresses, and can, thereby, result in
hysteresis.
If the mounting clips were perfectly elastic, or perfectly soft, then
they would not contribute to hysteresis. If, however, the clips undergo stress relief
during temperature cycling, then hysteresis can result. The magnitude of the hysteresis
produced by a given amount of stress relief is a function of the orientation of the
mounting clips with respect to the crystallographic axes of the quartz plate, [32] and the types of stresses.
For in-plane diametric forces, the force-frequency coefficient Kf
versus azimuth angle y have been found to have zeroes for
all the commonly used cuts, such as the AT and SC-cuts. [32]
Therefore, one might conclude that hysteresis due to stress relief in the mounting clips
can be eliminated by mounting the crystals where Kf = 0. Unfortunately,
it is not possible to completely eliminate the effects of mounting stresses in
conventional resonators for the following reasons. First, the azimuthal angles where Kf
=0 are functions of temperature, [33] so that there is no y where Kf = 0 over the whole temperature range of
a TCXO or MCXO. Second, the y where the effects of bonding
stresses are zero is different from the y where Kf
=0, at least for the AT-cut, the only cut for which bonding stress effects have
been reported. [35] Third, the forces due to the mounting clips are
generally not purely in-plane diametric forces. This is especially true for three and
fourpoint mounted resonators because, since the thermal expansion coefficient of quartz is
anisotropic whereas that of the typical package base is isotropic, the forces due to
temperature cycling will have tangential components. Similarly, for two-point mounted
resonators, the base's change of dimensions during temperature cycling will apply
shear-type forces in addition to the in-plane diametric forces.
Theoretically, property mounting the quartz resonator plate on an
identically oriented quartz plate, as is attempted in BVA resonators, [37]
ought to greatly reduce the hysteresis due to stress relief in the mounting structure. Our
literature search did not reveal evidence that BVA resonators exhibit hysteresis or
retrace that is superior to those found in high quality conventional resonators.
For an example of the frequency changes that can be caused by stress
relief, consider a 5-MHz third-overtone, 14-mm-diameter resonator. If one were to
intentionally mount this resonator at the y where Kf
is maximum, then the frequency shifts due to changes in the in-plane diametric forces
would be 2.9 X 10-8 per gram for an AT cut resonator, and 1.7 X 10-8
per gram for an SC-cut resonator [38] (where "per
gram" refers to the force due to a one gram weight, on earth).
The effects of electrode stress relief can be
minimized by using the SC-cut, [36] or by not having electrodes in
contact with the active area of the resonator, as can be done with BVA-type resonators, [37] and, to a lesser extent, with lateral field resonators [39]. Everything else being equal, using a single metal (e.g., Au) as
opposed to two or more metals (e.g., Cr-Au, Ti-Pd-Au) is also likely to produce lesser
stress relief effects because using two or more metals introduces additional interfaces
where stress relief and diffusion can occur.
Changes in the Quartz: Changes in the quartz due to the stresses
induced by temperature cycling are among the conceivable causes of hysteresis, although no
direct evidence of such changes could be uncovered in the literature. Perfect quartz would
not be expected to be affected by temperature cycling. The imperfections that are subject
to change include surface defects, dislocations. impurities, inclusions, and twins.
Surface defects. such as the microcracks produced by lapping, can
change upon temperature cycling, [40] however, by properly etching the
surfaces [41] subsequent to mechanical treatment, the possibility of
changes. can be greatly reduced or eliminated.
That dislocation motion due to temperature cycling is a factor in
hysteresis is unlikely at the typical TCXO temperatures. Even in sweeping experiments [42] that are usually conducted far above the normal operating
temperatures of oscillators. no evidence of dislocation motion has been reported. The
energy needed to anneal quartz damage due to neutron irradiation may be a clue to the
energies needed to move dislocations. When quartz is irradiated with fast neutrons.
displacement damage occurs. At high doses, the quartz gradually becomes disordered into an
amorphous form. Annealing studies on neutron damaged quartz indicate that the annealing
temperature of quartz is above the inversion temperature. [43]-[45] The activation energy for structure annealing is 0.75 eV [43].
" It takes a great deal less energy, however, to move impurities
in quartz to new lattice sites. Impurity motion due to temperature cycling is, therefore,
a more probable hysteresis mechanism than dislocation motion. It is possible to induce
impurity dependent effects, at more "normal" temperatures. For example, some
radiation- induced effects can anneal, [46] and low dc voltages
produce changes in the aging rates of resonators [47]. Normal sweeping
[7] requires temperatures of 4500C to 5000C and
field strengths of 1000 V/cm, but sweeping has been produced at room temperature ( » 230 C) when 25 V / mm is applied to a quartz bar [48]. Kusters [49] observed that when a 500 V/mm dc
field was applied to a doubly rotated quartz plate at 800C, the frequency shift
decayed with a time constant of 7 s. Moreover, there is evidence in the literature that
strain gradients due to ultrasonic vibrations can produce changes in quartz properties,
probably due to the motion of impurities down the gradients [50].
Recent experimental evidence developed at Hewlett-Packard seems to
support material defects being a significant mechanism. In two experimental groups of 38 LC-cuts
each (see Hammond [1]), significant differences were observed that
correlate with the quartz material. All fabrication processes other than the material were
identical. Optical grade quartz was irradiated to show the presence of defect centers. LC-cuts
made from darkened areas of the quartz formed the first group. LC-cuts from totally
clear areas formed the second group. As shown in Fig. 5, Group I had
a total yield of 34% with a high percentage of dead units and hysteresis rejects. Group 2
had a total yield of 84% with no hysteresis rejects. These crystals are operated on the
end of a 1/2 wave cable. Dead units are those for which the effective motional resistance
becomes so high at a particular temperature that the oscillator stops.
Fig. 5. Quartz LC- cuts. Effects of selected material. Quartz thermometer
Crystals, 28.2 MHz, third overtone. Group 1: Darkened quartz, yield 34%
Group 2: Clear quartz, yield 84%.
In a continuation of the work reported in Kusters and Kaitz, [8] normal sweeping was done on one group of natural quartz specimens, and extended sweeping done on a second group. All other processing parameters were identical. Sweeping was continued on the second group until the indicated ion current became stable and remained constant for at least 48 hours. Resistance data of finished pressure transducer resonators are shown in Figs. 6 and 7. There was a sharp difference between the two groups' motional resistances. There was also a sharp difference between the overall yields. Group I (Fig. 6) had a 64% yield; group 2 had a 93 % yield.
Fig. 6. Quartz pressure transducer resonator resistance readings, standard
electrodiffusion sweeping (5-MHz, third Overtone, BT cuts.
FIG. 7. Quartz pressure Transducer resonator resistance
readings,
Enhanced electrodiffusion sweeping (5MHz, third Overtone, BT-cuts).
Experimentally, in quartz LC-cuts and in the quartz pressure transducer
resonators, the hysteresis decreases as a result of continued thermal cycling thus
confirming the observations of Beaussier [23] that improved hysteresis
performance can result from thermal cycling.
Twins in a quartz plate can change under the influence of (high)
stresses. For example, when a sufficiently high stress is applied (0.5 GPa), it is
even possible to switch a single-domain crystal to a single domain of opposite polarity.
The removal of the stress leads to a complete restoration of the original orientation. The
stress-strain relations in a "ferrobielastic" material such as quartz can show
hysteresis due to ferrobielastic switching resulting from Dauphiné twin formation [51]. Twinning phenomena, however, are unlikely to be a significant
hysteresis mechanism because resonators that contain (macroscopic) twins would be rejected
during the usual inspection and testing procedures, because changes in twins tend to occur
suddenly, and because the stresses needed to move twin boundaries are probably higher than
the stresses due to temperature cycling. Changes in microtwins can possibly occur at high
pressures, in pressure transducers.
Other interesting thermal hysteresis phenomena in quartz take place
near 5730C, during the a -b
transition, [52], [53] in the incommensurate phase
of quartz. Various physical properties of quartz, such as the heat capacity and refractive
index, exhibit thermal hysteresis in this phase.
Apparent Hysteresis: Filler [11] showed
conclusively that when the thermometer in a compensated oscillator is separated from the
resonator (as it is in TCXO), the thermal gradients between the thermometer and the
resonator can produce "apparent" hysteresis. The apparent hysteresis can be
eliminated by using dual-mode self-temperature sensing [12], [13].
Angles-of-cut Dependence: Early data on SC-cut crystals seemed
to indicate that the SC-cut has lower hysteresis than AT- and BT-cuts.
A recent experiment on 30 SC cut, 10-MHz, third-overtone units and on 15 BT-cut,
5- MHz, third-overtone units in identical enclosures produced the data shown in Table 1.
The material in all was unswept cultured quartz with an IR "Q" of
nominally 2.5 million. The units had been cycled from 300C to 1500C
to 300C in temperature steps of 50C. Hysteresis was measured at the
turnover point of approximately 800C that corresponds roughly to the
temperature at which hysteresis is a maximum as defined in MIL-0-55310B. Hysteresis of
either sign was seen in both batches. The maximum seen was about +5 X -10-8
. This is essentially the same as reported in other work. [12]-[15] The experimental data are shown in Fig. 8.

Fig. 8. Worst-case thermal hysteresis: 30-1500C. Experimental hysteresis data:
SC-cut resonators are 10-MHz, third-Overtone: BT-cut resonators are 5 MHz,
Third overtone. ¨ SC-cuts.
· BT-cuts.
Oscillator Circuit Hysteresis: Hysteresis in circuit components can cause
oscillator hysteresis. For example, if a 20-pF load capacitor CL
is in series with a resonator and the resonator's C1 = 14 pF and C0
= 5 pF, then a 5 X 10-4 hysteresis in CL
produces a 1 X 10-7 f versus T
hysteresis [38].
Inductors are notorious for their instabilities; e.g., the windings of
inductors can stretch and move due to the stresses experienced during temperature cycling.
It is possible to minimize the circuit contributions to hysteresis by appropriate
resonator and circuit design, and circuit component selection. For example, the need for
inductors in the b-mode trap of SC-cut oscillators can be eliminated with
lateral field resonator designs that suppress the b-mode [54].
CONCLUSION
The results to date seem to indicate that lattice defects are somehow related to thermal hysteresis. Stress relief in the mounting structure can also produce significant hysteresis. As crystal processing techniques have improved, contamination has become less of a problem. This is shown in Fig. 9. The points represent a rough mean of the published data and demonstrate a two-order-of-magnitude reduction in the observed levels of hysteresis during the past 25 years.
Fig. 9. Measured hysteresis. AT- and SC-cuts. Hysteresis data quoted in Publications
rough averages computed when not available in original source). · Rough mean
That parts in 109 hysteresis has been observed in some resonators is encouraging. Once the effects of material defects and strain relief due to the mounting structure are better understood, and high-perfection quartz becomes available, it may be reasonable to expect parts in 109 hysteresis in a reproducible manner. MCXO's of parts in 109 f versus T stability will then be obtainable.
ACKNOWLEDGMENT
The authors thank Charles Adams, Jim Collin, and Leo Steindorf of Hewlett-Packard for sharing the results of the hysteresis reduction experiments in the LC-cut and pressure sensor, and for making the measurements on the SC-cut and BT-cut resonators, and Al Benjaminson of General Technical Services, Inc. for editing the section that reviews his work.
'(This specification is currently undergoing a
significant revision. Copies of the latest published revision of MIL-0-553 10 are
available from Naval
Publications and Forms Center. 5801 Tabor Ave. Philadelphia. PA 19120).
REFERENCES
[1] D. L. Hammond, C. A. Adams. and A. Benjaminson,
"Hysteresis effects in quartz resonators," in Proc. 22nd Annu. S,%mp. Freq.
Contr., 1968. pp. 55-66.
[2] L. A. Dick and J. F. Silver, "Low aging crystal units for use
in temperature compensated oscillators,- in Proc. 24th ASFC, 1970, pp. 141-146.
[3] G. E. Buroker and M. E. Frerking," A digitally compensated
TCXO,- in Proc. 27th ASFC. 1973, pp. 191-198.
[4] A. B. Mroch and G. R. Hykes, 16A miniature high stability TCXO
using digital compensation," in Proc. 30th ASFC, 1976. pp. 292300.
[5] H. J. F6rster, "Thermal hysteresis of AT + SC-cut
quartz crystal resonators: automated measurement method and results," in Proc.
36th ASFC, 1982, pp. 140-147.
[6] J. R. Vig, R. L. Filler. and J. A. Kosinski, "SC-cut
resonators for temperature compensated oscillators," in Proc. 36rh ASFC, 1982,
pp. 181-186.
[7] G. Kaitz, "Extended pressure and temperature operation on
BT-cut pressure transducers," in Proc. 38th ASFC, 1984, pp. 245-250.
[8] J. A. Kusters, and G. S. Kaitz. -Characteristics of natural. swept
natural, and cultured X- and Z-growth quartz material in high temperature, high stress
applications." in Proc.
39th ASFC, 1985, pp. 223-229.
[9] T. Ueda, F. Kohsaka. T. lino, and D. Yamazaki. "Temperature
sensor using quartz tuning fork resonator,- in Proc. 40th ASFC, 1986. pp. 224-229.
[10] R. W. Ward, and E. P. EerNisse, "A reduced hysteresis,
extended range quartz pressure transducer," in Proc. 41st ASFC, 1987. pp.
344-349.
[11] R. L. Filler, "Measurement and analysis of thermal
hysteresis in resonators and TCXO's, " in Proc. 42nd ASFC, 1988, pp. 380-388.
[12] R. L. Filler and J. R. Vig, "Resonators for the
microcomputer compensated crystal oscillator." in Proc. 43rd ASFC, 1989, pp.
8-15.
[13] S. S. Schodowski. "Resonator self-temperature-sensing using
a dualharmonic-mode crystal oscillator." in Proc. 43rd ASFC, 1989. pp. 2-7.
[14] R. L. Filler, "Thermal hysteresis in quartz crystal
resonators and oscillators, " in Proc. 44th Annu. S.ymp. Freq. Contr.. 1990,
pp. 176184.
[15] R. L. Filler, J. A. Messina. and V. J. Rosati, "Frequency
-temperature and aging performance of microcomputer compensated crystal oscillators,"
in Proc. 43rd ASFC, 1989, pp.
27-33.
[16] R. E. Bennett, Ed., "Quartz resonator handbook- Manu factu
ring guide for 'AT' type units," prepared for the Dept. of the Army by Union
Thermoelectric Div., Contract
DA36-039-SC-71061. pp. 195, 1960, AD 251289.
[17] A. Mroch, and G. Hykes, "High stability temperature
compensated crystal oscillator study," Research and Development Tech. Rep.
ECOM-73-0137-F, Final Rep., pp. 33, 36-42,
63-70, Feb. 1977, AD A036908.
[18] D. Symonds, and M. Wacker, "MACI adaptation of moderate
precision TCXO,- Research and Development Tech. Rep. SLCET-TR86-LO94-1. First Interim
Rep., pp. 1-10,
13-14, 23, 37-38. 63-70, July 1988, AD B126579.
[19] D. L. Hammond, C. A. Adams, and A. Benjaminson, "Hysteresis
effects in quartz resonators," Freq. Tech., vol. 7. no. 1, pp. 19-22, Jan.
1969.
[20] D. L. Hammond. and A. Benjaminson, "The crystal resonator-A
digital transducer," IEEE Spectrum, vol. 6, no. 4, pp. 53-58. Apr. 1969.
[21] K. K. Tuladhar, B. J. Adams, and E. D. Fletcher,
"Hysteresis effects in quartz crystal resonators," in Proc. IERE (British)
Int. Conf. Freq. Contr. & Synthesis; Univ. Surrey,
Guildford, UK, Apr. 1987, pp. 19-27.
[22] 1. 1. Tartakovskii, "Temperature hysteresis of frequency in
quartz resonators." Meas. Tech. (USA) vol. 30, no. 6. pp. 563-566, June 1987,
(translated from lzmeritel'nava
Tekhnika (USSR) vol. 30, no. 6, pp. 39-41,
June 1987).
[23] J. Beaussier, "Hysteresis thermique dans les resonateurs et
les oscillateurs a quartz," in Proc. 2nd Eur. Freq. Time Forum, Neuchatel,
Switzerland, pp. 803-815, Mar. 16-18,
1988.
[24] MIL-0-55310B, Military Specification, "Oscillators,
Crystal, General Specification for," May 10, 1988.
[25] T. C. Anderson et al., "Ground station frequency
standard," Bell Telephone Lab. Final Rep., RADC-TR-58-83, Jan. 9, 1958, AD 148769.
[26] R. A. Sykes, W. L. Smith. and W. J. Spencer, "Studies on
high precision resonators," in Proc. 17th ASFC, 1963, pp. 4-27.
[27] A. Benjaminson, "Advanced crystal oscillator design."
Final Report for Army Contract DAALOI-88-C-0804, to be published in 1991.
[28] R. A. Sykes, W. L. Smith, and W. J. Spencer, "Performance
of precision quartz-crystal controlled frequency generators," IRE Trans. Instrumentations.
vol. 1-11, pp. 245-247,
1962.
[29] J. H. Armstrong, P. R. Blomster, and J. L. Hokanson, "Aging
characteristics of quartz crystal resonators," in Prot-. 20th ASFC, 1966,
pp.192-207.
[30] R. Glang et al.. "High-vacuum technology," in Handbook
of Thin Film Technology, L. I. Maissel. and R. Glangg. Eds. pp. 2-39-2-49.
1970.
[31] J. H. Thomas, III, and S. P. Sarma, "Adsorption and
desorption of water on Au by the quartz-crystal-oscillator method.- J. Vac. Sci. Technol.,
vol. 13, pp. 549-551, 1976.
[32] A. Ballato, E. P. EerNisse. and T. Lukaszek. "The
force-frequency effect in doubly rotated quartz resonators." in Proc. 3 Ist ASFC, 1977.
pp. 8-16.
[33] E. P. EerNisse. 'bTemperature dependence of the force frequency
effect for the AT-, FC-, SC-, and Rotated X-cuts, - in Proc. 34th ASFC, 1980, pp.
426-430.
[34] E. D. Fletcher and A. J. Douglas, "A comparison of the
effects of bending moments on the vibrations of AT and SC (or TTC) cuts of quartz,"
in Proc. 33rd ASFC. 1979. pp.
346-350.
[35] R. L. Filler and J. R. Vig, "The effect of bonding on the
frequency vs. temperature characteristics of AT-cut resonators." in Prot-. 30th ASFC.
1976, pp. 264-268.
[36] E. P. EerNisse, "Quartz resonator frequency shifts arising
from electrode stress," in Proc. 29th ASFC. 1975, pp. 1-4.
[37] R. J. Besson and U. R. Peier, "Further advances on B.V.A.
resonators," in Proc. 34th ASFC, 1980. pp. 175-182.
[38] J. R. Vig, "Quartz crystal resonators and oscillators-For
frequency control and timing applications-A tutorial,- Tech. Rep. SLCET-TR88-1 (Rev. 4. 1)
Jan. 199 1. AD A231604.
(A later edition of this document is in print,
copies are available from the author.)
[39] A. Ballato, E. R. Hatch. M. Mizan, T. Lukaszek. and R. Tilton,
"Simple thickness modes driven by lateral fields." in Prot-. 39th ASFC. 1985.
pp. 462-472.
[40] B. M. Darinskii. N. V. lzmailov, et al., "Anelastic
relaxation in solids caused by surface damage," Sov. Ph.vs. Solid State, vol.
29. 1987, pp. 2023-2025.
[41] J. R. Vig, J. W. LeBus, and R. L. Filler, -Chernically polished
quartz," in Proc. 3 Ist ASFC, 1977. pp. 131-143.
[42] D. W. Han, J. Frank. D. Smith. J. J. Martin. and J. G.
Gualtieri. "A study of the electrodiffusion process in quartz." in Prot-. Annu.
Symp. Freq. Contr., 1990. pp. 222-227.
[43] F. B. Johnson, and R. S. Pease, "The pile irradiation of
quartz crystal oscillators," Phil. Mag., vol. 45. pp. 651-654, 1954.
[44] W. Primak, "Fast-neutron-induced changes in quartz and
vitreous silica." Ph ' vs. Rev., vol. 110. pp. 1240-1254. 1958.
[45] J. C. King and D. B. Fraser. "Effects of reactor
irradiation on thickness shear crystal resonators," in Proc. 16th ASFC. 1962.
pp. 8-3 1.
[46] J. J. Martin, -Alurninum-related acoustic loss in AT-cut quartz
crystals, " in Proc. 38th ASFC. 1984, pp. 16-2 1.
[47] R. L. Filler, J. A. Kosinski. V. J. Rosati. and J. R. Vig,
"Aging studies on quartz crystal resonators and oscillators," in-Proc. 38th ASFC,
1984, pp. 225-231.
[48] J. G. Gualtieri, private communication. Apr. 1990.
[49] J. A. Kusters. '*The effect of static electric fields on the
elastic constants of a-quartz," in Proc. 24th ASFC, 1970, pp. 46-54.
[50] R. R. Sharp and E. L. Pace, "Direct observation of impurity
motion in quartz using the raman effiect,- J. PhYs. Chem. Solids, vol. 31. pp.
2275-2279, 1970.
[51] E. Bertagnolli, E. Kittinger, and J. Tichy, "Ferrobielastic
hysteresis in ci-quartz," J. Appl. PhYs.. vol. 50, pp. 6267-6271, 1979.
[52] P. Bastie and G. Dolino. -y-ray-diffraction study of an
incommensurate phase: Application toquartz," Phvs. Rev. B, vol. 31, pp.
28572861, 1985.
[53] M. Matsuura, H. Yao, K. Gouhara, 1. Hatta, and N. Kato,
"Heat capacity in a-0 phase transition of quartz," J. PhYs. Soc. Japan. vol. 54,
pp. 625-629, 1985.
[54] M. Bloch. M. Meirs, and J. Ho, "The microcomputer
compensated crystal oscillator (MCXO),- in Proc. 43rd ASFC. 1989. pp. 16-19.
John
A. Kusters (S61-M64-SM87) was born in Racine, WI in 1937. He
received the B.S.E.E. degree in 1964 from Loyola University, Los Angeles, CA. He attended
Stanford University. Stanford. CA, from 1964 to 1968. working on microwave acoustic delay
lines. receiving the M.S.E.E. degree in 1965.
He worked at Hewlett-Packard from 1965 to 1986 developing cesium
frequency standards. acoustooptic devices, and quartz resonators. From 1986 to 1989 he
worked at the Efratom Division of Ball Corp. developing quartz resonators and oscillators.
In 1989. he returned to the Santa Clara Division of the Hewlett-Packard Co. where he is
currently the R&D Manager for Precision Time & Frequency products.
Mr. Kusters is a member of Tau Beta Pi. Sigma Xi. and Alpha Sigma
Nu.
John R. Vig (M72-SM84-F90)
was born in Hungary in 1942. He received the B.S. degree in physics from the City
College of New
York in 1964. and the M.S. and
Ph.D. degrees from Rutgers University. New Brunswick, NJ, in 1966 and 1969. respectively.
From 1969 to 1972 he served as an Officer in the U.S. Army,
stationed at the R&D laboratories of the Army Electronics Command. Fort Monmouth,
NJ. where he developed a
superconductive tunable filter. Since 1972 he has been employed as a civilian research
scientist at Fort Monmouth. working
primarily on the experimental
aspects of quartz crystal devices. Specific areas of interest have included the properties
of quartz, resonator fabrication
technology (cleaning, etching,
polishing. X-ray orienting, packaging, etc.), the effects of design and processing
parameters on stability, and the
developments of SC-cut crystals for
high-stability applications. He is currently Chief of the Frequency Control and Timing
Branch in the U.S. Army
Electronics Technology and Devices
Laboratory, Fort Monmouth. He leads a multidisciplinary research program aimed at the
development of high- stability
frequency control devices and clocks
for future Army communication, navigation, identification, and radar systems.
Dr.
Vig served as the General Chairman of the UFFC Society's Annual Frequency Control
Symposium from 1982 to 1988. Since 1972 he has been a
member of the Technical Program
Committee of the Frequency Control Symposium. He served from 1982 to 1986 as a member of
the Technical Program
Committee of the Quartz Devices
Conference, and since 1982. on the Executive Committee of the Precise Time and Time
Interval Applications and
Planning Meeting. He was appointed
to the IEEE Committee on Time and Frequency (TC-3) in 1979, and in 1985 as the IEEE
Representative on the
Hoover Medal Board of Award. He has
received the highest R&D award bestowed by the U.S. Army, the Army Research and
Development
Achievement Award. in 1979, 1983.
and 1987. The results of his research have been presented at symposia and have been
published in more than 70