| Title Page |
| Copyright Page |
| Technical Program Committee |
| Session Reference |
| Table of Contents |
| |
| U1-A-1 | Ultrasound-Induced Coalescence of Free Gas Microbubbles - M. Postema, P. Marmottant, C. T. Lancée, M. Versluis, S. Hilgenfeldt and N. de Jong |
| U1-A-2 | Perfusion Estimation Using Subharmonic Contrast Microbubble Signals - F. Forsberg, J. B. Liu, W. T. Shi, R. Ro, K. M. James, X. Deng and A. L. Hall |
| U1-A-3 | Assessment of Transient Myocardial Perfusion Defects in Intact Mice Using a Microbubble Contrast Destruction/Refill Approach - J. A. Hossack, Y. Li, Z. Yang and B. A. French |
| U1-A-4 | Identification of Ultrasound-Contrast-Agent Dilution Systems for Cardiac Quantification - M. Mischi, A. A. C. M. Kalker and H. H. M. Korsten |
| U1-A-5 | Quantitative Laser Doppler Anemometry Measurements of the Shear-Stresses Exerted on Ultrasonic Microbubbles Attached to Surfaces Under Physiological Flow Conditions - M. B. Butler, C. M. Moran, T. Anderson, C. Cunningham, J. A. Ross, W. Easson, K. A. A. Fox and W. N. McDicken |
| U1-A-6 | Physico-Chemical Properties of the Microbubble Lipid Shell: Composition, Microstructure & Properties of Targeted Ultrasound Contrast Agents - M. A. Borden, P. Dayton, S. Zhao and K. W. Ferrara |
| U2-A-1 | Shear Wave Elastography: Modeling of the Shear Wave Propagation in Heterogeneous Tissue by Pseudospectral Method - S. Callé, J.-P. Remenieras, M. E. Hachemi and F. Patat |
| U2-A-2 | 3D Ultrasound-Based Dynamic and Transient Elastography: First In Vitro Results - J. Bercoff, R. Sinkus, M. Tanter and M. Fink |
| U2-A-3 | Noise Minimization by Multicompression Approach in Elasticity Imaging - H. Du, J. Liu, C. Pellot-Barakat and M. F. Insana |
| U2-A-4 | Automated Thermal Coagulation Segmentation of Three-Dimensional Elastographic Imaging Using an Active Contour Model - W. Liu, J. A. Zagzebski, T. Varghese, C. R. Dyer and U. Techavipoo |
| U2-A-5 | Estimation of Displacement Vectors and Strain Tensors in Elastography Using Angular Insonifications - U. Techavipoo, Q. Chen, T. Varghese and J. A. Zagzebski |
| U2-A-6 | Adaptable Coded Excitation for Elasticity Imaging - J. Liu and M. F. Insana |
| U3-A-3 | A Novel Technique for Enhancing the Signal to Noise of Laser-Based Ultrasonic Systems - O. Balogun, N. Pratt and T. W. Murray |
| U3-A-4 | Optical Measurement of Transient Ultrasonic Shock Waves - X. Jacob, C. Barrière, R. Takatsu, G. Montaldo and D. Royer |
| U4-A-1 | Acousto-Optic Properties of Photonic Crystal Fibers - M. W. Haakestad and H. E. Engan |
| U4-A-2 | FDTD Analysis of Wavelength-Selective Switching in Weighted Acoustooptic Switches for WDM Photonic Routers - N. Goto and Y. Miyazaki |
| U4-A-3 | New Architecture of Tunable Acoustooptical Add/Drop Multiplexer for Dynamic DWDM with 25 GHz ITU Grid - A. Tsarev and E. Kolosovsky |
| U4-A-4 | High Frequency Ultrasound Detection Using Fabry-Perot Optical Etalon - S. Ashkenazi, T. Buma and M. O'Donnell |
| U4-A-5 | Characteristics of Acoustooptic Devices for Generating Symmetric Diffracted Scanning Beams - D. L. Hecht |
| U4-A-6 | The Formation of Two-Beam Technological Laser with Use of the High Efficiency Acoustooptic Modulator - S. N. Antonov, V. V. Proklov, Y. G. Rezvov, L. N. Chesnokov and V. N. Chesnokov |
| U5-A-1 | Evaluation of the P-Matrix Parameters Frequency Variation Using Periodic FEM/BEM Analysis - T. Pastureaud |
| U5-A-2 | Modified P-Matrix Model and its Implementation for Design of SAW Resonator Filters - A. N. Rusakov |
| U5-A-3 | Wavelets Constructed from Spectral Domain Asymptotic Tails of Green's Functions - A. R. Baghai-Wadji and G. G. Walter |
| U5-A-4 | Quasi-Static Transduction in Mechanically Reflective Gratings, with Application to STW Transducers - D. P. Morgan |
| U5-A-5 | Fast Calculation of the Gradient and the Difference Vector of IDT’s P Matrix - G. Martin |
| U5-A-6 | On the Polynomial Approximation of the Dispersive COM-Parameters - B. V. Sveshnikov, V. I. Cherednick and K. K. Bhattacharjee |
| U1-B-2 | Portable, Low-Cost Medical Ultrasound Device Prototype - M. I. Fuller, K. Ranganathan, S. Zhou, T. N. Blalock, J. A. Hossack and W. F. Walker |
| U1-B-3 | Real Time 3D Ultrasound Imaging of the Brain - N. M. Ivancevich, K. K. Chu, J. D. Dahl, E. D. Light, G. E. Trahey, S. F. Idriss, P. D. Wolf, E. Dixon-Tulloch and S. W. Smith |
| U1-B-4 | 3D Contrast Harmonic Echocardiography - M. M. Voormolen, A. Bouakaz, B. J. Krenning, C. T. Lancée, A. E. van den Bosch, W. B. Vletter, F. J. ten Cate, A. F. W. van der Steen and N. de Jong |
| U1-B-5 | Increasing Frame Rate in Ultrasound Imaging by Temporal Morphing Using Tissue Doppler - S. Brekke, C. B. Ingul, S. A. Aase and H. G. Torp |
| U2-B-1 | Finite Element Analysis of Temperature Rise from an Integrated 3-D Intracardiac Echo and Ultrasound Ablation Transducer - K. L. Gentry, M. L. Palmeri, N. Sachedina and S. W. Smith |
| U2-B-2 | Feasibility of Noninvasive Transesophageal Cardiac Thermal Ablation Using an Ultrasound Phased Array - X. Yin, L. M. Epstein and K. Hynynen |
| U2-B-3 | Aberration Correction by Nonlinear Beam-Mixing: Generation of a Pseudo Point Sound Source - J. Seo, J. J. Choi, T. L. Hall, J. B. Fowlkes, M. O'Donnell and C. A. Cain |
| U2-B-4 | A HIFU System Using Annular and Strip-Electrode Arrays with a Digital Diagnostic Array System - R. Muratore, F. L. Lizzi, P. Lee, S. N. Ramachandran and A. Kalisz |
| U2-B-6 | In Situ Thermal Parameter Estimation for HIFU Therapy Planning and Treatment Monitoring - A. Anand, L. Byrd and P. J. Kaczkowski |
| U3-B-1 | Prototype Dual Frequency Bilaminar Array Transducer Capable of Therapeutic Exposure at 500 kHz and Doppler Monitoring at 2MHz - T. Azuma, S.-i. Umemura, M. Ogihara, J. Kubota, T. Kobayashi, M. Izumi, A. Sasaki and H. Furuhata |
| U3-B-2 | Design of a Multi-Layer Transducer for Acoustic Bladder Volume Assessment - E. J. W. Merks, N. Bom, A. Bouakaz, N. de Jong and A. F. W. van der Steen |
| U3-B-3 | Real-Time 3D Color Doppler for Guidance of Vibrating Interventional Devices - M. P. Fronheiser, P. D. Wolf, S. F. Idriss, R. C. Nelson, E. Dixon-Tulloch and S. W. Smith |
| U3-B-4 | Finite Element Modeling of Ultrasonic Separation at the Microscale - M. K. Araz, C.-H. Lee and A. Lal |
| U3-B-5 | Two-Dimensional Ultrasound Detection with an Optical Multilayer Hydrophone Using Serial and Parallel Data Acquisition - M. Klann and C. Koch |
| U3-B-6 | Piezoelectric Transducer Surface Vibration Characterization Using Acoustic Holography and Laser Vibrometry - O. A. Sapozhnikov, A. V. Morozov and D. Cathignol |
| U4-B-1 | Growth of AlN Film on Mo/SiO2/Si (111) for 5GHz-Band FBAR Using MOCVD - C.-M. Yang, K. Uehara, Y. Aota, S.-K. Kim, S. Kameda, H. Nakase, Y. Isota and K. Tsubouchi |
| U4-B-2 | Re-Growth of C-Axis Oriented AlN Thin Films - F. Martin, P. Muralt, M. Cantoni and M.-A. Dubois |
| U4-B-3 | PZT Material Properties at UHF and Microwave Frequencies Derived from FBAR Measurements - J. D. Larson III, S. R. Gilbert and B. Xu |
| U4-B-4 | Frequency Sensitive Reflection, Refraction, and Transmission of Bulk and Shear Waves in Functionally Graded Materials - J. Vollmann, D. M. Profunser and J. Dual |
| U4-B-5 | Acoustoelectronics: History, Present State, and New Ideas for a New Era (Invited) - Y. V. Gulyaev and F. S. Hickernell |
| U5-B-1 | Study of Layered SAW Devices Operating at Different Modes for Gas Sensing Applications - K. Kalantar-zadeh, D. A. Powell, S. Ippolito and W. Wlodarski |
| U5-B-2 | High SAW Velocity and High Electromechanical Coupling Coefficient with the New Three Layered Structure: ZnO/AlN/Diamond - M. El Hakiki, O. Elmazria, M. B. Assouar, V. Mortet, A. Talbi and F. Sarry |
| U5-B-4 | Diamond-Based SAW Oscillator at 1GHz - V. U. Prechtel, V. Ziegler, S. Kolodzik, B. Plehn, H. Downar, J. Haering, R. Kunze, G. Martin, H. Schmidt and M. Weihnacht |
| U5-B-5 | Fabrication of 5-GHz-Band SAW Filter with Atomically-Flat-Surface AlN on Sapphire - K. Uehara, C.-M. Yang, T. Shibata, S.-K. Kim, S. Kameda, H. Nakase and K. Tsubouchi |
| U1-C-2 | Microbubble Surface Modes - M. Versluis, S. M. van der Meer, D. Lohse, P. Palanchon, D. Goertz, C. T. Chin and N. de Jong |
| U1-C-3 | Air Bubble in an Ultrasound Field: Theoretical and Optical Results - P. Palanchon, A. Bouakaz, M. Versluis and N. de Jong |
| U1-C-4 | Novel Method of Micro Bubble Manipulation by Self Organization in Ultrasonic Wave - Y. Yamakoshi |
| U1-C-5 | Understanding the Pulse-to-Pulse Evolution of Microbubble Clouds Using Light Scattering - J. Guan and T. J. Matula |
| U2-C-1 | Spatial and Temporal Stability of Tissue Induced Aberration - J. J. Dahl, M. S. Soo and G. E. Trahey |
| U2-C-2 | A New Adaptive Imaging Technique Using Optimal Aperture Size - M.-L. Li and P.-C. Li |
| U2-C-3 | High Resolution Ultrasonic Brain Imaging: Noninvasive Adaptive Focusing Based on Twin Arrays - F. Vignon, J. F. Aubry, M. Tanter and M. Fink |
| U2-C-4 | Resolution Improvement of Point Targets by Real-Time Phase Aberration Correction: In Vivo Results - S. A. McAleavey, J. J. Dahl, M. S. Soo, G. F. Pinton and G. E. Trahey |
| U2-C-5 | Refocusing Dual-Mode Ultrasound Arrays in the Presence of Strongly Scattering Obstacles - H. Yao and E. S. Ebbini |
| U2-C-6 | Synthetic Aperture Angular Scatter Imaging: System Refinement - D. A. Guenther, K. Ranganathan, M. J. McAllister, W. F. Walker and K. W. Rigby |
| U3-C-1 | A Simple Distributed Model for cMUT - F. Patat, F. Teston, N. Felix and D. Certon |
| U3-C-2 | Dynamic FEM Analysis of Multiple cMUT Cells in Immersion - B. Bayram, G. G. Yaralioglu, A. S. Ergun, Ö. Oralkan and B. T. Khuri-Yakub |
| U3-C-3 | Analytical Calculation of Collapse Voltage of CMUT Membrane - A. Nikoozadeh, B. Bayram, G. G. Yaralioglu and B. T. Khuri-Yakub |
| U3-C-4 | Modeling and Design of CMUTs Using Higher Order Vibration Modes - N. A. Hall, R. O. Guldiken, J. McLean and F. L. Degertekin |
| U3-C-5 | Accurate Modeling of CMUTs (Invited) - R. Lerch, M. Kaltenbacher, A. Hauck, G. Link and M. Hofer |
| U4-C-1 | Application of a DC Bias to Reduce Acceleration Sensitivity in Quartz Resonators - M. Patel and Y.-K. Yong |
| U4-C-2/PS1-11 | Dedicated Finite Elements for Electrode Thin Films on Quartz Resonators (Student Paper) - S. A. Srivastava, Y.-K. Yong, M. Tanaka and T. Imai |
| U4-C-3 | Optimization of Frame-Like Film Bulk Acoustic Resonators for Suppression of Spurious Lateral Modes Using Finite Element Method - J.-H. Lee, C.-M. Yao, K.-Y. Tzeng, C.-W. Cheng and Y.-C. Shih |
| U4-C-4 | Prediction of BAW Resonator Performance Using Experimental and Numerical Methods - R. Thalhammer, J. Kaitila, R. Aigner and S. Marksteiner |
| U4-C-5 | Excitability of Ultrasound Generated by Magnetostriction - V. J. Sánchez Morcillo, V. Espinosa, J. Redondo, F. Camarena and J. Martinez-Mora |
| U4-C-6 | Simulation of Magnetostatic Soliton Generation and Propagation in Thin YIG Films Using Equivalent Circuit Technique - T. Koike, R. Marcelli and G. Bartolucci |
| U5-C-1 | DMS Filter with Reduced Resistive Losses - G. Kovacs, W. Sauer and T. Bauer |
| U5-C-2 | A Low-Loss and Wide-Band DMS Filter Using Pitch-Modulated IDT and Reflector Structures - O. Kawachi, S. Mitobe, M. Tajima, T. Yamaji, S. Inoue and K.-y. Hashimoto |
| U5-C-3 | Evolution of the SAW Transducer for Communication Systems (Invited) - D. C. Malocha |
| U5-C-4 | Experimental Results for a Longitudinally Coupled 5-IDT Resonator Filter with Distributed Gaps - J. Meltaus, S. Härmä, M. M. Salomaa and V. P. Plessky |
| U6-C-1 | Electrode Optimization for a Lateral Field Excited Acoustic Wave Sensor - M. Meissner, L. A. French Jr., W. Pinkham, C. York, G. Bernhardt, M. Pereira da Cunha and J. F. Vetelino |
| U6-C-2 | Kinetic Reaction Monitoring of Acidified Milk Gels with a Quartz Resonator: Effect of Temperature and GDL Quantities - C. Ould Ehssein, S. Serfaty, P. Griesmar, E. Caplain, L. Martinez and M. Gindre |
| U6-C-3 | Gelation Monitoring by Quartz Microbalance in Pulse Mode - E. Caplain, C. Ould Ehssein, L. Martinez, S. Serfaty, P. Griesmar and M. Gindre |
| U6-C-4 | Use of a Quartz Crystal Resonator to Study the Cell Adhesion Process - D. Le Guillou-Buffello, M. Gindre, V. Migonney and P. Laugier |
| U6-C-5 | Sensitivity Enhancement of a QCM Biosensor Using Polymer Treatment - M. Z. Atashbar, B. Bejcek, A. Vijh and S. Singamaneni |
| U6-C-6 | Quartz Thickness Shear Mode Resonators for Living Cells Based Functional Biosensors - F. Li, J. H.-C. Wang, T. Shun and Q.-M. Wang |
| U1-D-1 | New Contrast Imaging Method Using Double Frequency Exposure - A. Bouakaz and N. de Jong |
| U1-D-2 | The Resonance Frequency of SonoVue™ as Observed by High-Speed Optical Imaging - S. M. van der Meer, M. Versluis, D. Lohse, C. T. Chin, A. Bouakaz and N. de Jong |
| U1-D-3 | Determining Thresholds for Contrast Agent Collapse - A. Y. Ammi, J. Mamou, G. I. Wang, R. O. Cleveland, S. L. Bridal and W. D. O'Brien Jr. |
| U1-D-4 | Acoustic Detection of Controlled Bubble Creation by LIOB in Tissue-Mimicking Gelatin Phantoms - C. Tse, M. J. Zohdy, J. Y. Ye, T. B. Norris, L. Balogh, K. W. Hollman and M. O'Donnell |
| U1-D-5 | U2: Combined Ultrasonic Microscopy and Ultrafast Optics for Molecular Imaging and Therapy (Invited) - M. O'Donnell, C. Tse, M. Zohdy, T. Erpelding, K. Hollman, J. Y. Ye, T. B. Norris and L. Balogh |
| U2-D-2 | Assessment of Vulnerable Coronary Plaque by Intravascular Elasticity Imaging - T. Shiina, N. Nitta, H. Endo and M. Yamagishi |
| U2-D-3 | Young's Modulus Reconstruction for Assessing Vulnerable Atherosclerotic Plaque Composition In Vivo - R. A. Baldewsing, J. A. Schaar, F. Mastik, C. W. J. Oomens and A. F. W. van der Steen |
| U2-D-4 | Non-Invasive High-Frequency Vascular Ultrasound Elastography: In Vitro and In Vivo Phantom Investigations - R. L. Maurice, M. Daronat, F. S. Foster and G. Cloutier |
| U2-D-5 | Estimation of 2D Displacement and Strain Field in High Frequency Ultrasound Based Elastography - M. Vogt, C. Perrey and H. Ermert |
| U2-D-6 | Arterial Elastic Modulus Reconstruction from In-Vivo Strain Image Using Arterial Pressure Equalization - K. Kim, W. F. Weitzel, J. M. Rubin, H. Xie, X. Chen and M. O'Donnell |
| U3-D-1 | Medical Imaging with Capacitive Micromachined Ultrasound Transducer (cMUT) Arrays (Invited) - D. M. Mills |
| U3-D-2 | Integrated Ultrasonic Imaging Systems Based on CMUT Arrays: Recent Progress - I. O. Wygant, X. Zhuang, D. T. Yeh, A. Nikoozadeh, O. Oralkan, A. S. Ergun, M. Karaman and B. T. Khuri-Yakub |
| U3-D-3 | A cMUT Linear Array Used as Echographic Probe: Fabrication, Characterization, and Images - G. Caliano, R. Carotenuto, E. Cianci, V. Foglietti, A. Caronti and M. Pappalardo |
| U3-D-4 | High-Frequency CMUT Arrays for High-Resolution Medical Imaging - Ö. Oralkan, S. T. Hansen, B. Bayram, G. G. Yaralioglu, A. S. Ergun and B. T. Khuri-Yakub |
| U3-D-5 | CMUT Ring Arrays for Forward-Looking Intravascular Imaging - Ö. Oralkan, S. T. Hansen, B. Bayram, G. G. Yaralioglu, A. S. Ergun and B. T. Khuri-Yakub |
| U4-D-1 | Wide Bandwidth Thin Film BAW Filters - K. M. Lakin, C. W. Andrus, J. R. Belsick, K. T. McCarron and W. H. Thornhill |
| U4-D-2 | Narrow Band Bulk Acoustic Wave Filters - H. P. Loebl, C. Metzmacher, R. F. Milsom, R. Mauczok, W. Brand, P. Lok, A. Tuinhout and F. Vanhelmont |
| U4-D-3 | Single-to-Balanced Filters for Mobile Phones Using Coupled Resonator BAW Technology - G. G. Fattinger, J. Kaitila, R. Aigner and W. Nessler |
| U4-D-4 | Demonstration of a Novel 2.0 mm x 1.6 mm x 0.9 mm PCS Tx Filter with Steep Pass Band Rolloffs & High Rejection - D. Feld, P. Bradley, B. Yu and D. Lee |
| U4-D-5 | 3.8×3.8 mm² PCS-CDMA Duplexer Incorporating Thin Film Resonator Technology - H. Heinze, E. Schmidhammer, C. Diekmann and T. Metzger |
| U4-D-6 | New Electrode Material for Low-Loss and High-Q FBAR Filters - T. Yokoyama, T. Nishihara, S. Taniguchi, M. Iwaki, Y. Satoh, M. Ueda and T. Miyashita |
| U5-D-1 | Performances of Short Reflectors on 128° LiNbO3 - S. Lehtonen, V. P. Plessky, N. Béreux and M. M. Salomaa |
| U5-D-2 | Calculation of the SAW-Induced Stress Distributions in an Electrode of a SAW-Device on LiTaO3 - F. Kubat, W. Ruile, U. Rösler, C. C. W. Ruppel and L. M. Reindl |
| U5-D-3 | A Novel Piezoelectric Interdigital Transducer for the Excitation of High Frequency Surface Acoustic Waves - W. Daniau, A. K. Sarin Kumar, P. Paruch, D. Marré, J.-M. Triscone and S. Ballandras |
| U5-D-4 | Fast FEM/BEM Computation of SAW Harmonic Admittance and Slowness Curves - V. Laude, A. Reinhardt, S. Ballandras, A. Khelif and M. Solal |
| U5-D-6 | RF-SAW Filters on Pyro-Suppressed Wafers - K. Vetelino, P. Welsh, M. Aguirre and B. Abbott |
| U1-E-2 | High Frequency Ultrasound Speckle Flow Imaging: Comparison with Doppler Optical Coherence Tomography (DOCT) - V. X. D. Yang, A. Needles, D. Vray, S. Lo, B. C. Wilson, I. A. Vitkin and F. S. Foster |
| U1-E-3 | Limitations of Dual Frequency Measurements for Embolus Classification - D. H. Evans |
| U1-E-4 | Implantable Doppler System for Self-Monitoring Vascular Grafts - D. Vilkomerson and T. Chilipka |
| U1-E-5 | High Frequency B-Mode Ultrasound Blood Flow Estimation in the Microvasculature - D. Vray, A. Needles, V. X. D. Yang and F. S. Foster |
| U2-E-1 | Ultrasonic Strain and Strain Rate Imaging for the Assessment of Regional Myocardial Function in Mice - J. D'hooge, D. Thijs, K. Sipido, P. Claus, B. Bijnens, J. Thoen, F. Van de Werf, G. R. Sutherland and P. Suetens |
| U2-E-2 | Automatic Detection and Tracking of Left Ventricular Landmarks in Echocardiography - A. H. Torp, S. I. Rabben, A. Støylen, H. Ihlen, K. Andersen, L.-Å. Brodin and B. Olstad |
| U2-E-3 | A Model Based Approach to Estimate Contractile Force Development Using Myocardial Velocity Imaging: A Validation Study During Alterations in Contractility and Heart Rate - M. Mc Laughlin, P. Claus, P. Mehwald, M. Marciniak, J. D'hooge, G. R. Sutherland and B. Bijnens |
| U2-E-4 | Viscoelasticity Measurement of Heart Wall in In Vivo - H. Kanai |
| U2-E-5 | A New Method for Two-Dimensional Myocardial Strain Estimation by Ultrasound: An In-Vivo Comparison with Sonomicrometry - S. Langeland, J. D'hooge, H. A. Leather, P. Claus, G. R. Sutherland, P. F. Wouters and B. Bijnens |
| U2-E-6 | A New Multifrequency Transducer for Microemboli Detection and Classification - P. Palanchon, A. Bouakaz, J. Klein and N. de Jong |
| U3-E-1 | Microfabricated Ultrasonic Transducers Monolithically Integrated with High Voltage Electronics - C. Daft, S. Calmes, D. da Graca, K. Patel, P. Wagner and I. Ladabaum |
| U3-E-2 | A Novel Method for Fabricating Capacitive Micromachined Ultrasonic Transducers with Ultra-Thin Membranes - L. L. Liu, O. M. Mukdadi, C. F. Herrmann, R. A. Saravanan, J. R. Hertzberg, S. M. George, V. M. Bright and R. Shandas |
| U3-E-3 | CMUTs with Dual Electrode Structure for Improved Transmit and Receive Performance - J. McLean, R. O. Guldiken and F. L. Degertekin |
| U3-E-4/PS1-19 | Optimized Membrane Configuration Improves CMUT Performance (Student Paper) - Y. Huang, E. O. Hæggström, X. Zhuang, A. S. Ergun and B. T. Khuri-Yakub |
| U3-E-5 | PZT Driven Micromachined 2-D Membrane Arrays - S. Ardanuç and A. Lal |
| U4-E-1/PS1-14 | Combined Radiation Pressure Field in a Dual-Frequency Ultrasound System (Student Paper) - J. S. Thierman, G. T. Clement and K. Hynynen |
| U4-E-2 | Perfectly Matched Layer for FDTD Computations in Piezoelectric Crystals - F. Chagla, C. Cabani and P. M. Smith |
| U4-E-3 | Acoustic Scattering by Few Close Shells: Comparison Between Experience and Theory - P.-Y. Le Bas and P. Pareige |
| U4-E-4 | Elastic Waves in Deviated Boreholes in Formations with Triaxial Stresses - B. K. Sinha and Q.-H. Liu |
| U4-E-5 | Influence of Periodical Stiffeners on the Acoustic Response of a Finite Cylindrical Shell - R. Liétard, D. Décultot, G. Maze and M. Tran-Van-Nhieu |
| U4-E-6 | Propagation of Nonlinear Acoustic Signals through Inhomogeneous Moving Media - V. A. Khokhlova, P. Blanc-Benon, M. V. Averianov and R. O. Cleveland |
| U5-E-1 | Observation and Control of Solidification Processes by Ultrasonic Pulse-Echo Technique - A. Drevermann, C. Pickmann, L. Sturz and G. Zimmermann |
| U5-E-2 | Ultrasonic In-Situ Monitoring of Solidification and Melting Behaviors of an Aluminum Alloy - I. Ihara, D. Burhan and Y. Seda |
| U5-E-3 | Real-Time Monitoring of Fabrication Process of Microfluidic Plastic Devices Using Miniature Ultrasonic Sensors - Y. Ono, C.-C. Cheng, M. Kobayashi, C.-K. Jen, N. Nardini and B. Gauthier |
| U5-E-4 | Super-Resolution In Situ Ultrasonic Monitoring of Chemical Reactions - A. N. Kalashnikov, K. L. Shafran, R. E. Challis, C. C. Perry, M. E. Unwin, A. K. Holmes and V. Ivchenko |
| U5-E-6 | Transmission of Acoustic Waves through Piezoelectric Plates: Modeling and Experiment - E. Le Clezio and A. Shuvalov |
| U6-E-1 | Axial Transmission Techniques for Bone Assessment: An In Vitro Comparative Study - M. Muller, P. Moilanen, M. Talmant, V. Kilappa, P. Nicholson, J. Timonen, S. Cheng and P. Laugier |
| U6-E-2 | Application of the Kramers-Kronig Relations to Measurements of Attenuation and Dispersion in Cancellous Bone - K. R. Waters, B. K. Hoffmeister and J. A. Javarone |
| U6-E-3 | Ultrasonic Wave Dispersion and Attenuation in a Periodically Two-Layered Medium - L. Yu, L. H. Le and M. D. Sacchi |
| U6-E-4 | Characterization of Human Femoral Trabecular Bone In Vitro Using Transmission and Backscatter Ultrasound Measurements - F. Jenson, F. Padilla, F. Peyrin, P. Cloetens, V. Bousson, C. Bergot, J.-D. Laredo, C. Latremouille and P. Laugier |
| U6-E-5 | Acoustic Microscopy for Detection of Osteoporotic Bone Properties - J. Brandt, A. Franke and K. Raum |
| U6-E-6 | Impact of Material and Structural Bone Properties on 1-MHz Velocity Measurements in Human Forearms - E. Bossy, M. Talmant, L. Akrout, P. Laugier, F. Peyrin and P. Cloetens |
| U1-F-1 | Quantitative Blood Flow Estimation Error Due to the In-Plane Component of the Flow with Intravascular Ultrasound - F. J. de Ana and M. O'Donnell |
| U1-F-2 | ECG-Triggered Retrospective Colour Flow Imaging - R. Williams, A. Needles, A. Duckett, E. Cherin and F. S. Foster |
| U1-F-3 | Clutter-Free Doppler Detection of Signed Velocity Based on Legendre Series Expansion - S.-i. Umemura, T. Azuma and T. Hayashi |
| U1-F-4 | Real-Time Simultaneous Assessment of Wall Distension and Wall Shear Rate in Carotid Arteries - G. Bambi, T. Morganti, S. Ricci, F. Guidi and P. Tortoli |
| U1-F-5 | Complex Blind Source Separation for Acoustic Radiation Force Impulse Imaging in the Peripheral Vasculature, In Vivo - C. M. Gallippi and G. E. Trahey |
| U1-F-6 | Real-Time Blood Motion Imaging: A 2D Blood Flow Visualization Technique - L. Loevstakken, S. Bjaerum, D. Martens and H. Torp |
| U2-F-1 | Towards Understanding the Nature of High Frequency Backscatter from Cells and Tissues: An Investigation of Backscatter Power Spectra from Different Concentrations of Cells of Different Sizes - M. C. Kolios, G. J. Czarnota, A. Worthington, A. Giles, A. S. Tunis and M. D. Sherar |
| U2-F-2 | Evaluation of the Layered Structure of Aortic Valve Cusps Using High-Frequency Ultrasound - Q. Qiu, J. Dunmore-Buyze, D. R. Boughner and J. C. Lacefield |
| U2-F-3 | The Response of Regional Integrated Backscatter Levels and Regional Strain to Inotropic Stimulation and Acute Ischemia - J. D'hooge, S. Coenen, O. Turschner, P. Claus, M. McLaughlin, P. Mehwald, M. Marciniak, C. Dommke, B. Bijnens, G. R. Sutherland and P. Suetens |
| U2-F-4 | Silicon Based Ultrasonic Microprobes for Cardiac Signal Recording - X. Chen, A. Lal, M. L. Riccio and R. F. Gilmour |
| U2-F-5 | Mechanical Properties of Single Cells: Measurement Possibilities Using Time-Resolved Scanning Acoustic Microscopy (Invited) - R. M. Lemor, E. C. Weiss, G. Pilarczyk and P. V. Zinin |
| U3-F-1 | The Effect of Pillar Misalignment on the Underwater Performance of High Frequency Multilayer 1-3 Piezocomposite Transducers with Acoustic Matching and Backing Layers - J. F. Saillant, S. Cochran, R. Berriet, K. Kirk and G. Fleury |
| U3-F-2 | Application of Optimisation Techniques to Finite Element Analysis of Piezocomposite Devices - P. Reynolds and V. Pereyra |
| U3-F-3/PS1-20 | Inverse Calculation Method for Piezocomposite Materials Characterization (Student Paper) - G. Férin, D. Certon, J. Guyonvarch and N. Félix |
| U3-F-4 | Modeling of the Temperature Increase in Ultrasonic Transducers - V. Loyau, G. Feuillard and L. P. Tran-Huu-Hue |
| U3-F-5 | A Method for the Measurement of the k Factor in Lossy Piezoelectric Materials - N. Lamberti, A. Iula and M. Pappalardo |
| U3-F-6 | FEA and Experimental Characterization of Langevin Transducers with Comparable Longitudinal and Lateral Dimensions - A. Iula, D. Cerro, M. Pappalardo and N. Lamberti |
| U4-F-1 | Guiding and Filtering Acoustic Waves in a Two-Dimensional Phononic Crystal - A. Khelif, A. Choujaa, S. Benchabane, V. Laude and B. Djafari-Rouhani |
| U4-F-2 | Measuring Permeability of Porous Materials via Acoustic Transmitted Waves - Z. E. A. Fellah, J. Y. Chapelon, N. Sebaa, W. Lauriks, C. Depollier and M. Fellah |
| U4-F-3 | Material Property Measurement in Hostile Environments Using Laser Acoustics (Invited) - K. L. Telschow |
| U4-F-4 | Forward Modeling for Ultrasonic Leaky Lamb-Wave Based Imaging through a Highly Contrasting Steel Cylindrical Layer - S. Zeroug |
| U4-F-5 | Measurement of Static and Dynamic Radiation Force on Spheres - S. Chen, G. Silva, R. Kinnick, M. Fatemi and J. F. Greenleaf |
| U5-F-1 | Ultrasonic Imaging of Fingerprints Using Acoustical Impediography (Invited) - R. M. Schmitt, W. G. Scott, R. D. Irving, J. Arnold, C. Bardons, D. Halpert and L. Parker |
| U5-F-2 | The Elastic Properties of Hamster Kidney Cells Evaluated by Ultrasonic Atomic Force Microscopy - A. M. Ebert, J. Du, X. Wang and B. Tittmann |
| U5-F-3 | Multi-Frequency Ultrasonic NDE for Early Defect Recognition and Imaging - K. Pfleiderer, J. Aufrecht, I. Solodov and G. Busse |
| U5-F-4 | 3D Ultrasonic Imaging and Contour Detection in Sheet Metal Hydroforming - O. Keitmann-Curdes, K. Hensel, P. Knoll, H. Meier and H. Ermert |
| U5-F-5 | Optimized Algorithm for Synthetic Aperture Imaging - T. Stepinski and F. Lingvall |
| U6-F-1 | MRI-Based Thermometry and Thermal Dosimetry During Focused Ultrasound Thermal Ablation of Uterine Leiomyomas - N. McDannold, C. Tempany, E. A. Stewart, F. A. Jolesz and K. Hynynen |
| U6-F-2 | Cavitation Enhances Treatment Depth when Combined with Thermal Effect Using a Plane Ultrasound Transducer: An In Vivo Study - C. Goldenstedt, D. Melodelima, F. Mithieux, S. Chesnais, Y. Theillère and D. Cathignol |
| U6-F-3 | Feasibility of MRI-Guided Transurethral Thermal Therapy for Prostate Cancer - R. Chopra, M. Burtnyk, S. N. Baker, V. Choy, S. Lochhead and M. J. Bronskill |
| U6-F-4 | Detection of Imaging Acoustic Signals for Synchronizing a Commercial Ultrasound Imager with a High Intensity Focused Ultrasound Therapy System - N. R. Owen, M. R. Bailey, P. J. Kaczkowski, W. Kreider and L. A. Crum |
| U6-F-5 | Temperature Rise Measured Noninvasively During Thermal Therapy Using Backscattered Ultrasound - P. J. Kaczkowski and A. Anand |
| U6-F-6 | Noninvasive Localized Ultrasonic Measurement of Tissue Properties - H. Yao, R. Griffin and E. S. Ebbini |
| U1-G-2 | Acoustic Radiation Force Impulse Imaging of In Vivo Breast Masses - A. C. Sharma, M. S. Soo, G. E. Trahey and K. R. Nightingale |
| U1-G-3/PS1-1 | Bubble-Based Acoustic Radiation Force for Monitoring Intraocular Lens Elasticity (Student Paper) - T. N. Erpelding, K. W. Hollman, T. Juhasz and M. O'Donnell |
| U1-G-4 | Abdominal Acoustic Radiation Force Impulse Imaging - B. J. Fahey and G. E. Trahey |
| U1-G-5 | High Frequency Elastography for In-Vivo Study of the Mechanical Behavior of Skin - Y. Mofid, F. Ossant, F. Patat, C. Imberdis and G. Josse |
| U1-G-6 | Acoustic Radiation Force Impulse (ARFI) Imaging of the Gastrointestinal Tract - M. Palmeri, K. Frinkley, L. Zhai, R. Bentley, K. Ludwig, M. Gottfried and K. Nightingale |
| U2-G-1 | Comparison of 3D Deformable Models for In Vivo Measurements of Mouse Embryo from 3D Ultrasound Images - B. Qiu, P. Clarysse, J. Montagnat, M. Janier and D. Vray |
| U2-G-2 | Ultrasound B-Mode 360° Tomography in Mice - P. R. Hoskins, T. Anderson, M. Sharp, S. Meagher, T. McGillivray and W. N. McDicken |
| U2-G-3 | Comparison and Validation of High Frequency Ultrasound Detection Techniques in a Mouse Model for Renal Tumors - E. Jouannot, J.-P. Duong-Van-Huyen, K. Bourahla, P. Laugier, M. Lelievre-Pegorier and L. Bridal |
| U2-G-4 | Performance of a 50 MHz Annular Array Based Imaging System - J. A. Brown, C. Morton-Démoré, F. S. Foster and G. R. Lockwood |
| U2-G-5 | High Resolution Ultrasound Imaging of Skeletal Muscle Dynamics and Effects of Fatigue - R. S. Witte, D. E. Dow, R. Olafsson, Y. Shi and M. O'Donnell |
| U2-G-6 | High Frequency Ultrasound Signal Statistics from Mouse Mammary Tissue During Involution - A. S. Tunis, D. Spurrell, D. McAlduff, A. Giles, M. Hariri, R. Khokha, M. D. Sherar, G. J. Czarnota and M. C. Kolios |
| U3-G-1 | Clinical Application and Technical Challenges for Intracardiac Ultrasound Imaging: Catheter Based ICE Imaging with EP Mapping (Invited) - D. N. Stephens, K. K. Shung, J. Cannata, J. Zhao, R. Chia, H. Nguyen, K. Thomenius, A. Dentinger, D. G. Wildes, X. Chen, M. O'Donnell, R. I. Lowe, J. Pemberton, G. H. Burch and D. J. Sahn |
| U3-G-2 | Real-Time 3D Transesophageal Echocardiography - E. C. Pua, S. F. Idriss, P. D. Wolf and S. W. Smith |
| U3-G-3 | 3D Ultrasound Imaging System Using Fresnel Ring Array & High Voltage Multiplexer IC - S. Tamano, T. Kobayashi, S. Sano, K. Hara, J. Sakano and T. Azuma |
| U3-G-4PS1-22 | Real-Time 3D Ultrasound with Multiple Transducer Arrays (Student Paper) - M. P. Fronheiser, E. D. Light and S. W. Smith |
| U3-G-5 | Advances in Two Dimensional Arrays for Real Time 3D Intravascular Ultrasound - E. D. Light, S. W. Smith and J. F. Angle |
| U4-G-1 | A Variational Principle for the Equations of Viscopiezoelectricity - P. C. Y. Lee and N. P. Edwards |
| U4-G-3 | The Stokes Relations Linking Time Reversal and the Inverse Filter - F. Vignon, A. Saez, J. F. Aubry, M. Tanter and M. Fink |
| U4-G-4 | 2D Pseudo-Array Using an Ultrasonic One Channel Time-Reversal Mirror - N. Quieffin, S. Catheline, R. K. Ing and M. Fink |
| U5-G-1 | Anti-Collision Methods for Global SAW RFID Tag Systems - C. Hartmann, P. Hartmann, P. Brown, J. Bellamy, L. Claiborne and W. Bonner |
| U5-G-2 /PS1-9 A9 | Dual Configuration High Temperature Hydrogen Sensor on LGS SAW Devices (Student Paper) - J. A. Thiele and M. Pereira da Cunha |
| U5-G-3/PS1-10 | A Theoretical Study of Love Wave Sensors Mass Loading and Viscoelastic Sensitivity in Gas and Liquid Environments (Student Paper) - C. Zimmermann, P. Mazein, D. Rebière, C. Déjous, F. Josse and J. Pistré |
| U5-G-4 | SAW Sensor for Anti-Human-Immuno-Globulin G Molecule Detection - Y. Roh, Y. Hur and Y. E. Pak |
| U5-G-6 | Ultrasonic Measurement of Molar Fractions in Gas Mixtures by Orthogonal Signal Correction - J. E. Carlson and P.-E. Martinsson |
| U6-G-1 | High Resolution Ultrasonography of Retinal Degeneration in Rat - C. Jolly, J. C. Jeanny, F. Behar-Cohen, P. Laugier and A. Saied |
| U6-G-2 | High Frequency Ultrasound in Monitoring Liver Suitability for Transplantation - R. M. Vlad, G. J. Czarnota, A. Giles, M. D. Sherar, J. W. Hunt and M. C. Kolios |
| U6-G-3 | New Developments in Tissue-Type Imaging (TTI) for Guiding Prostate Biopsies and for Planning and Monitoring Treatment of Prostate Cancer - E. J. Feleppa, J. Ketterling, P. Lee, S. Urban, A. Kalisz, C. R. Porter, G. Kutcher and F. Arias-Mendosa |
| U6-G-4 | The Intensity Reflection Coefficient: A Novel Method for Investigating Blood - A. Amararene, F. Yu and G. Cloutier |
| U6-G-5 | Attenuation Compensated Spectral Slopes during the Kinetics of Rouleaux Formation for Porcine Whole Blood in Couette Flow at 10-70 MHz - F. Yu, D. Savéry, A. Amararene, F. S. Foster and G. Cloutier |
| U6-G-6 | High Frequency Ultrasound Characterization of the Coagulation Process of Whole Blood - F. Ossant, R. Libgot, P. Coupé, P. Lermusiaux and F. Patat |
| U1-H-1 | Time Reversal Acoustics (Invited) - M. Fink, G. Montaldo and M. Tanter |
| U1-H-2 | A Novel Phase Aberration Measurement Technique Derived from the DORT Method: Comparison with Correlation-Based Method on Simulated and In-Vivo Data - M. R. Burcher, A. T. Fernandez and C. Cohen-Bacrie |
| U1-H-4 | Experimental Comparisons of the Impact of Abdominal Wall Aberrators on Linear and Nonlinear Beam Patterns - K. D. Wallace, B. S. Robinson, M. R. Holland, M. R. Rielly and J. G. Miller |
| U1-H-5 | Efficient and Accurate Spline-Based Time Delay Estimation - F. Viola and W. F. Walker |
| U2-H-1 | Effect of Pulse Parameters on Cavitation and Acoustic Streaming in Ultrasonic Surgical Devices - M. E. Schafer |
| U2-H-3 | Spatial Control of Cavitation: Theoretical and Experimental Validation of a Dual-Frequency Excitation Method - S. D. Sokka, T. P. Gauthier and K. Hynynen |
| U2-H-4 | Heating Mechanism of Microbubbles and Bubble Properties - Y. Kaneko, J. S. Allen, S. Yoshizawa and Y. Matsumoto |
| U2-H-5 | Nonlinear Ultrasound Propagation in a Spherical Bubble Cloud - S. Yoshizawa, T. Ikeda, S. Takagi and Y. Matsumoto |
| U2-H-6 | Bubble Interactions in Clouds Produced During Shock Wave Lithotripsy - E. A. Zabolotskaya, Y. A. Ilinskii, G. D. Meegan and M. F. Hamilton |
| U3-H-1 | Development of a High Frequency (35 MHz) Linear Ultrasonic Array Using 2-2 Composite Elements - J. M. Cannata, Q. F. Zhou and K. K. Shung |
| U3-H-2 | Piezocomposite 30MHz Linear Array for Medical Imaging: Design Challenges and Performances Evaluation of a 128 Elements Array - S. Michau, P. Mauchamp and R. Dufait |
| U3-H-3/PS1-21 | Wide Frequency Band and High Intensity Thickness Vibration of Hydrothermal Lead Zirconate Titanate Polycrystalline Film (Student Paper) - M. Ishikawa, M. K. Kurosawa, A. Endoh and S. Takeuchi |
| U3-H-4 | Shear Wave Transducer Using (1120) Textured ZnO Film - T. Yanagitani, M. Matsukawa, Y. Watanabe and T. Otani |
| U3-H-5 | Lead-Free Thick Piezoelectric Films as Miniature High Temperature Ultrasonic Transducers - M. Kobayashi, C.-K. Jen, Y. Ono and S. Krüger |
| U4-H-1 | Development of Strong Elasticoluminescence from Ferroelectric Phase - C.-N. Xu, H. Yamada, X. Wang and X.-G. Zheng |
| U4-H-2 | Spherical f 1mm SAW Device Based on Ball Semiconductor/MEMS Technology - D. Sim, A. Mizukami, S. Akao, I. Satoh, M. Bryan, N. Takeda, T. Ohgi, N. Nakaso, T. Miyagishi, H. Tanaka, K. Fukiura, H. Kazato, H. Watanabe, T. Mihara and K. Yamanaka |
| U4-H-5 | High Frequency Filters Based on Piezoelectrically Transduced Micromechanical Resonators - L. Yan, J. Wu and W. C. Tang |
| U4-H-6 | Piezoelectric Micromechanical Disk Resonators Towards UHF Band - L. Yan, J. Wu and W. C. Tang |
| U5-H-1 | Optimized Excitation Sources and Exact Solutions for Ultrasonic Field Propagation in a Nonlinear Medium with Hysteretic Behavior - S. Dos Santos, L. Haumesser, F. Vander Meulen, O. Bou Matar and V. Gusev |
| U5-H-2 | A Novel Numerical Method for Simulating Wave Propagation in Moving Media - M. Bezdek, A. Rieder, H. Landes, R. Lerch and W. Drahm |
| U5-H-3 | Analysis of Ultrasonic Wave Propagation in Metallic Pipe Structures Using Finite Element Modelling Techniques - A. Gachagan, A. McNab and P. Reynolds |
| U5-H-4 | Wave Propagation in Transversely Isotropic Cylinders - F. Honarvar, E. Enjilela, S. A. Mirnezami and A. N. Sinclair |
| U5-H-5 | Experimental Study of a Sharp Bending Wave-Guide Constructed in a Sonic-Crystal Slab of an Array of Short Aluminum Rods in Air - T. Miyashita |
| U5-H-6 | A Computational Method to Calculate the Transmit-Receive Mode Echo Responses from Targets of Complex Geometry - F. Buiochi, O. Martínez, L. Gómez-Ullate and F. M. de Espinosa |
| U6-H-1 | A Miniaturized 3 x 3-mm SAW Antenna Duplexer for the US-PCS Band with Temperature-Compensated LiTaO3/Sapphire Substrate - J. Tsutsumi, S. Inoue, Y. Iwamoto, M. Miura, T. Matsuda, Y. Satoh, T. Nishizawa, M. Ueda and O. Ikata |
| U6-H-2 | US-PCS SAW Duplexer Using High-Q SAW Resonator with SiO2 Coat for Stabilizing Temperature Characteristics - R. Takayama, H. Nakanishi, Y. Iwasaki, T. Sakuragawa and K. Fujii |
| U6-H-3 | Improved Rejection Band in SAW Ladder Filters Using High Frequency Shunt Element - J. J. Caron and S. L. Shishkin |
| U6-H-4 | SAW Duplexers without l/4 Phase Shifter for CDMA Cellular Phone Systems - T. Onzuka, K. Noguchi, S. Yoshimoto and Y. Yamamoto |
| U6-H-5 | Investigation of SAW W-CDMA Antenna Duplexer and GSM-Based FEM Including Duplexer - M. Hikita, N. Shibagaki, K. Sakiyama, H. Sunayama and K. Tachibatake |
| U6-H-6 | A SAW Duplexer with Superior Temperature Characteristics for US-PCS - G. Kovacs, W. Ruile, M. Jakob, U. Rösler, E. Maier, U. Knauer and H. Zottl |
| U1-I-1 | A Two-Step Procedure for Optimization of Contrast Sensitivity and Specificity of Post-Beamforming Volterra Filters - M. F. Al-Mistarihi, P. Phukpattaranont and E. S. Ebbini |
| U1-I-2 | Spectral Compensation for Tissue Attenuation and Transmit Intensity in Ultrasonic Detection of Microbubbles by Harmonic Method - S. Chen, M. Fatemi, E. McMahon, J. F. Greenleaf and M. Belohlavek |
| U1-I-3 | High Frequency Nonlinear Scattering and Imaging of a Submicron Contrast Agent - D. E. Goertz, M. E. Frijlink, N. de Jong and A. F. W. van der Steen |
| U1-I-4 | High Frequency Contrast Imaging - Y. Sun, D. E. Kruse, P. A. Dayton and K. W. Ferrara |
| U2-I-1 | Large Volume Blood-Brain Barrier Disruption by Low Frequency Focused Ultrasound: A Method for Targeted Drug Delivery and Molecular Imaging - K. Hynynen, N. McDannold, N. Vykhodtseva, S. Raymond, F. A. Jolesz and N. Sheikov |
| U2-I-2/PS1-4 | Transcranial MRI-Guided Focused Ultrasound-Induced Blood-Brain Barrier Opening in Rats (Student Paper) - L. H. Treat, N. McDannold, N. Vykhodtseva and K. Hynynen |
| U2-I-3 | Schlieren Observation of Therapeutic Field in Water Surrounded by Cranium Radiated from 500 kHz Ultrasonic Sector Transducer - T. Azuma, K.-i. Kawabata, S.-i. Umemura, M. Ogihara, J. Kubota, A. Sasaki and H. Furuhata |
| U2-I-4 | Prediction of the Skull Overheating During High Intensity Focused Ultrasound Transcranial Brain Therapy - M. Pernot, J.-F. Aubry, M. Tanter, F. Andre and M. Fink |
| U2-I-5 | The Use of Optison to Reduce the Power Requirements for Focused Ultrasound Lesion Production in the Brain: An MRI/Histology Study in Rabbits - N. Vykhodtseva, N. McDannold and K. Hynynen |
| U2-I-6 | Ultrasonic Transcranial Brain Therapy: First In Vivo Clinical Investigation on 22 Sheep Using Adaptive Focusing - M. Pernot, J.-F. Aubry, M. Tanter, A. L. Boch, M. Kujas and M. Fink |
| U3-I-1 | High Coupling KNbO3 Width-Extensional Vibrators with a Polar Multidomain Structure - H. Koyama, K. Nakamura and T. Takano |
| U3-I-2 | Multilayer PMN-PT Single Crystal Transducer for Medical Application - S. M. Rhim, H. Jung and K.-J. Lee |
| U3-I-3 | A Multirow Single Crystal Phased Array for Wideband Ultrasound Imaging - M. J. Zipparo, C. G. Oakley, D. M. Mills, A. M. Dentinger and L. S. Smith |
| U3-I-4 | Broad Band Single Crystal Transducer for Contrast Agent Harmonic Imaging - W. Hackenberger, X. Jiang, P. W. Rehrig, X. Geng, A. Winder and F. Forsberg |
| U3-I-5 | Characterization of High Frequency Transducers with Wire Target and Hydrophone - B. Huang and K. K. Shung |
| U4-I-1 | Ultrasonic Field Measurement in Test Cells Combining the Acousto-Optic Effect, Laser Interferometry & Tomography - G. Harvey, A. Gachagan and A. McNab |
| U4-I-4 | Tunable Phononic Band Gaps of Surface and Bulk Acoustic Waves in Two-Dimensional Phononic Crystals - T.-T. Wu and Z.-G. Huang |
| U4-I-5 | Full Band Gaps for Surface Acoustic Waves in Piezoelectric Phononic Crystals - V. Laude, M. Wilm, S. Benchabane and A. Khelif |
| U5-I-1 | Optimization of an Array Based Pulse-Echo System for Identification of Reflector Geometry - P. C. Pedersen and A. Nadkarni |
| U5-I-2 | Ultrasonic Flaw Detection Using Discrete Wavelet Transform for NDE Applications - E. Oruklu and J. Saniie |
| U5-I-3/PS1-8 | Performance Assessment of a Kalman Filter-Based Method for Ultrasonic Time-of-Flight Estimation (Student Paper) - L. Angrisani, A. Baccigalupi and R. S. Lo Moriello |
| U5-I-4 | Ensemble of Classifiers Approach for NDT Data Fusion - D. Parikh, M. T. Kim, J. Oagaro, S. Mandayam and R. Polikar |
| U5-I-5 | Broadband Ultrasonic Attenuation Measurements Using Coded Sweep Excitations - R. P. B. da Costa-Félix and J. C. Machado |
| U5-I-6 | Theoretical and Experimental Study of Time Reversal in Anisotropic Medium - B. Zhang, M. Lu and C. Wang |
| U6-I-1 | SAW in China (Invited) - Y. Shui |
| U6-I-2 | Orthogonal Frequency Coding for SAW Device Applications - D. C. Malocha, D. Puccio and D. Gallagher |
| U6-I-3 | The New Approach to Realize Small Imbalances in Differential Rx-Outputs for SAW Front End Module - O. Hikino, M. Kijima, K. Yokoyama, M. Ohki, N. Matsuura, K. Sakiyama and M. Hikita |
| U6-I-4 | Modular Integration of RF SAW Filters - M. P. Goetz and C. E. Jones |
| U1-J-1 | Remote Manipulation of Cells with Ultrasound and Microbubbles - A. van Wamel, A. Bouakaz, M. Versluis and N. de Jong |
| U1-J-2 | Optical and Ultrasonic Monitoring of Laser-Generated Intracellular Contrast Agents: Initial Cell Culture Studies - M. J. Zohdy, C. Tse, J. Y. Ye and M. O'Donnell |
| U1-J-3 | In Vitro Acoustic Molecular Imaging of Tissue Factor Expressed by Smooth Muscle Cells with Stable Liquid Perfluorocarbon Nanoparticle Contrast Agents - J. N. Marsh, K. C. Crowder, M. S. Hughes, M. J. Scott, E. K. Lacy, G. M. Lanza and S. A. Wickline |
| U1-J-4 | In Vivo Ultrasonic Detection of Angiogenesis with Site-Targeted Nanoparticle Contrast Agents Using Measure-Theoretic Signal Receivers - M. S. Hughes, J. N. Marsh, J. Allen, P. A. Brown, E.K. Lacy, M. J. Scott, G. M. Lanza, S. A. Wickline and C. S. Hall |
| U1-J-5 | Acoustic Radiation Force Enhances Adhesion of Microbubbles Targeted to P-Selectin - J. J. Rychak, A. L. Klibanov and J. Hossack |
| U1-J-6/PS1-3 | Increasing Binding Efficiency of Ultrasound Targeted Agents with Radiation Force (Student Paper) - S. Zhao, M. Borden, S. H. Bloch, D. E. Kruse, K. W. Ferrara and P. A. Dayton |
| U2-J-1/PS1-2 | Intravascular Ultrasound Tissue Harmonic Imaging In Vivo (Student Paper) - M. E. Frijlink, D. E. Goertz, L. C. A. van Damme, R. Krams and A. F. W. van der Steen |
| U2-J-2 | Computerized Segmentation of Blood and Luminal Borders in Intravascular Ultrasound - C. Perrey, U. Scheipers, W. Bojara, M. Lindstaedt, S. Holt and H. Ermert |
| U2-J-3 | 'Blind' Data Calibration of Intravascular Ultrasound Data for Automated Tissue Characterization - A. Nair, D. G. Vince and D. Calvetti |
| U2-J-4 | Application of Ultrasonic Thermal Imaging in IVUS Systems - Y. Shi, R. S. Witte, F. J. de Ana, X. C. Chen, H. Xie and M. O'Donnell |
| U2-J-6 | Analysis of Blood Clot Formation with Transient Elastography: Similarity with Sol-Gel Transition in Agar-Gelatin Phantoms - J.-L. Gennisson, F. Yu and G. Cloutier |
| U3-J-1 | Ferroelectrets: Highly Anisotropic Electrically Charged Polymer Foams for Electromechanical Transducer Applications - M. Wegener, E. Tuncer, W. Wirges, R. Gerhard-Multhaupt, M. Dansachmüller, S. Bauer-Gogonea, R. Schwödiauer and S. Bauer |
| U3-J-2 | Ferroelectrets: Ultrasonic Transducer for a Biomimetic Sonar System - A. Streicher, R. Müller, H. Peremans, M. Katenbacher and R. Lerch |
| U3-J-3 | Semi-Quantitative Piezoelectric Activity Testing in Polymer Layers - C. B. Nilsen, C. M. Gregory and J. V. Hatfield |
| U3-J-4 | Piezoelectric Material Nonlinearity Identification via Multiharmonic Finite Elements - B. Kaltenbacher, M. Kaltenbacher, M. Hofer and R. Lerch |
| U3-J-5 | New Low Acoustic Impedance Piezoelectric Material for Broadband Transducer Applications - M. Lethiecq, F. Levassort, L.-P. Tran-Huu-Hue, M. Alguero, L. Pardo, T. Bove, E. Ringgaard and W. Wolny |
| U3-J-6 | Piezoelectric Ceramics with High Dielectric Constants for Ultrasonic Medical Transducers - Y. Hosono and Y. Yamashita |
| U4-J-1 | A Novel Approach for High Power Ultrasonic Linear Motors - T. Hemsel, M. Mracek, J. Wallaschek and P. Vasiljev |
| U4-J-2/PS1-13 | An Ultrasonic Linear Motor Using Ridge Mode Traveling Waves (Student Paper) - M. Tominaga, R. Kaminaga, J. R. Friend, K. Nakamura and S. Ueha |
| U4-J-3 | Analysis of Bidirectional Vibrational Transport of Small Objects by Periodic Wave Trains of Pulses - V. G. Mozhaev and A. V. Zyrianova |
| U4-J-4 | Analytical and Numerical Modeling of an Ultrasonic Stepping Motor Using Standing Waves - J. M. Fernandez, M. Krummen and Y. Perriard |
| U4-J-5 | Precise Position Control of Ultrasonic Motor Using Fuzzy Control - H. Li, C. Zhao and C. Gu |
| U4-J-6 | Development of an Arrayed-Type Multi-Degree-of-Freedom Ultrasonic Motor Based on a Selection of Reciprocating Vibration Modes - K. Otokawa and T. Maeno |
| U5-J-1 | Ultrasonic Tomography Application to the Visualization of Air Flow (Invited) - F. Cohen Tenoudji, V. Dewailly, J. F. Mourey, J. P. Frangi and G. Theron |
| U5-J-2 | Operating Principles of the Monolithic Cylinder Gyroscope - B. Kanani |
| U5-J-3 | Ultrasonic Micrometer Position Indicator with Temperature Compensation - M. Pedrick and B. R. Tittmann |
| U5-J-4 | On the Sensitivity of Corrosion and Fatigue Damage Detection Using Guided Ultrasonic Waves - P. Fromme, P. D. Wilcox, M. J. S. Lowe and P. Cawley |
| U6-J-1 | Existence of Harmonic Metal Thickness Mode Propagation for Longitudinal Leaky Waves - M. Solal, R. Lardat, T. Pastureaud, W. Steichen, V. P. Plessky, T. Makkonen and M. M. Salomaa |
| U6-J-2 | Optimized Cut of Lithium Niobate for HVPSAW Filters with Different Metalization Ratio in Element Resonators - N. Naumenko and B. Abbott |
| U6-J-3/PS1-18 | Evaluation of Material Constants and SAW Properties in LaCa4O(BO3)3 Single Crystals (Student Paper) - H. Shimizu, H. Takeda, T. Nishida, S. Okamura, T. Shiosaki and T. Shikida |
| U6-J-4 | Properties of Radio Frequency Rayleigh Waves on Langasite at Elevated Temperatures - R. Fachberger, G. Bruckner, R. Hauser, C. Ruppel, J. Biniasch and L. Reindl |
| U6-J-5 | Analysis of the SAW Propagation in Langasite Crystal by X-Ray Topography - D. V. Roshchupkin, H. D. Roshchupkina, D. V. Irzhak and O. A. Buzanov |
| U6-J-6 | Acoustic Waves on Plane Interfaces in Piezoelectric Bi-Crystalline Structures of Specific Types - A. N. Darinskii and M. Weihnacht |
| U1-K-1 | High-Frequency Ultrasound Characterization of Pulmonary Arterial Wall Under Normoxic and Hypoxic Conditions - K. R. Waters |
| U1-K-2 | Improved Accuracy of Vascular Wall Shear Rate Measurements - J. K. Tsou, J. Liu, C. Pellot-Barakat and M. F. Insana |
| U1-K-3 | Comparison of Ultrasound Radiation Force and Fluid Pressure Generated Waves in Arterial Vessels - X. Zhang, R. R. Kinnick, M. Fatemi and J. F. Greenleaf |
| U1-K-4 | 3D Simulations of Difference Frequency Effects on a Blood Vessel in Ultrasound-Stimulated Vibro-Acoustography - J. Heikkilä, T. Karjalainen, M. Vauhkonen and K. Hynynen |
| U1-K-5 | Detection of Shear Wave Propagation in an Artery Using Pulse Echo Ultrasound and Kalman Filtering - Y. Zheng, S. Chen, X. Zhang and J. F. Greenleaf |
| U1-K-6 | Transcutaneous Measurement of Viscoelasticity of Arterial Wall by Application of Remote Actuation - H. Hasegawa and H. Kanai |
| U2-K-1 | Spatial Coding with Curved Wavefronts - R. Zemp and M. F. Insana |
| U2-K-2 | Two-Dimensional Blind Iterative Deconvolution of Medical Ultrasound Images - R. Jirík and T. Taxt |
| U2-K-3 | A Flexible Algorithm for Layout-Optimized Sparse cMUT Arrays - A. Austeng, J. E. Kirkebø and S. Holm |
| U2-K-4 | Rectilinear 3-D Ultrasound Imaging Using Synthetic Aperture Techniques - N. M. Daher and J. T. Yen |
| U2-K-5 | Curved Two-Dimensional Arrays in Ultrasound - J. E. Kirkebø, A. Austeng and S. Holm |
| U2-K-6 | A 3x3 Matrix Beam-Former of Partially Overlapping Beams Using a 1.5 D Array for Real Time Cross-Correlation Imaging (CCI) - R. M. Schmitt, W. G. Scott, J. B. Fowlkes, O. D. Kripfgans, R. Irving, J. M. Rubin and P. L. Carson |
| U3-K-1 | Ultrasonic Lamb Wave NDE System Using an Air Coupled Concave Array Transducer - M. J. Garcia-Hernandez, J. A. Chavez, Y. Yañez, H. B. Kichou, J. L. Prego-Borges, J. Salazar, A. Turo and F. Montero de Espinosa |
| U3-K-3 | Miniature, High Efficiency Transducers for Use in Ultrasonic Flow Meters - S. G. Joshi, B. D. Zaitsev and I. E. Kuznetsova |
| U3-K-4 | Efficient Generation and Measurement of Guided Torsional Waves Using Magnetostrictive Nickel Patches - C. I. Park, S. H. Cho, S. W. Han and Y. Y. Kim |
| U3-K-5 | A 5MHz Piezocomposite Ultrasound Array for Operations in High Temperature and Harsh Environment - C. Devallencourt, S. Michau, C. Bantignies and N. Felix |
| U4-K-1 | A Cylindrical Micro Ultrasonic Motor Using a Micro-Machined Bulk Piezoelectric Transducer - T. Kanda, A. Makino, K. Suzumori, T. Morita and M. K. Kurosawa |
| U4-K-2 | Design and Testing of a 4-mm³ Bidirectional Linear Microfin Actuator - J. Friend, Y. Gouda, K. Nakamura and S. Ueha |
| U4-K-3 | Numerical Study on Scattering of Rayleigh Wave by Silicon Slider Projections for SAW Motor - Y. Miyazaki, T. Shigematsu, M. K. Kurosawa and Y. Ishigami |
| U4-K-4 | Very Fast Scanning Probe for Ophthalmic Echography Using an Ultrasound Motor - R. Carotenuto, G. Caliano, A. Caronti, A. Savoia and M. Pappalardo |
| U4-K-5 | Single Crystal Ultrasonic Motor for Cryogenic Actuations - X. N. Jiang, P. W. Rehrig, W. S. Hackenberger, S. Dong and D. Viehland |
| U4-K-6 | An Autonomous Self-Powered Acoustic Transmitter Using Radioactive Thin Films - R. Duggirala, H. Li and A. Lal |
| U6-K-1 | Temperature Compensated LiTaO3/Sapphire Bonded SAW Substrate with Low Loss and High Coupling Factor Suitable for US-PCS Application - M. Miura, T. Matsuda, Y. Satoh, M. Ueda, O. Ikata, Y. Ebata and H. Takagi |
| U6-K-2 | Low Resistance Quartz Resonators for Automotive Applications without Spurious Modes - M. Mayer, A. Bergmann, K. Wagner, M. Schemies, T. Telgmann and A. Glas |
| U6-K-3 | Wideband Love Wave Filters Operating in GHz Range on Cu-Grating/Rotated-YX-LiNbO3-Substrate Structure - K.-y. Hashimoto, H. Asano, K. Matsuda, N. Yokoyama, T. Omori and M. Yamaguchi |
| U6-K-4 | Theoretical and Experimental Results of Unidirectional Interdigital Transducers Using Grating SAW Substrates and Zero TCF Ladder Type Filters at 2GHz-Range - K. Yamanouchi and Y. Satoh |
| U6-K-5 | Phase Sensitive Optical Measurements and Numerical Simulations of a Fan-Shaped Filter - K. Kokkonen, P. Dufilie, J. V. Knuuttila and M. M. Salomaa |
| U6-K-6 | A Study of Electrostatic Discharge Effects of the SAW Pattern by the FDTD Method - K.-Y. Lin and K.-H. Lin |
| PS1-5 | FPGA Based Digital High Frequency Beamformers for Arrays (Student Paper) - C.-h. Hu, K. A. Snook, X.-c. Xu, J. T. Yen, K. K. Shung and P.-j. Cao |
| PS1-6 | Ultrasound-Guided HIFU Neurolysis of Peripheral Nerves to Treat Spasticity and Pain (Student Paper) - J. L. Foley, J. W. Little, F. L. Starr III, C. Frantz and S. Vaezy |
| PS1-7 | Counter-Propagating Lamb-Wave Pair for Nondestructive Evaluation (Student Paper) - M. Suzuki and T. Hoshimiya |
| PS1-12 | Visualization of In- and Out-of-Plane Vibrations in a Micromechanical RF-Resonator (Student Paper) - O. Holmgren, K. Kokkonen, T. Mattila, V. Kaajakari, A. Oja, J. Kiihamäki, J. V. Knuuttila and M. M. Salomaa |
| PS1-15 | Minimizing the Bulk Scattering Loss in CRF(DMS) Devices (Student Paper) - W. Wang, X. Zhang, Y. Shui, H. Wu, D. Zhang and V. P. Plessky |
| PS1-16 | SAW and BAW Response of c-axis AlN Thin Films Sputtered on Platinum (Student Paper) - M. Clement, L. Vergara, J. Olivares, E. Iborra, J. Sangrador, A. Sanz-Hervás and C. Zinck |
| PS1-17 | FEM/BEM Impedance and Power Analysis for Measured LGS SH-SAW Devices (Student Paper) - T. D. Kenny, T. B. Pollard, E. J. Berkenpas and M. P. da Cunha |
| PS1-27 | Effects of Electric Bias and O2 Content on Properties of ZnO Films and Characterization of ZnO-Based Film Bulk Acoustic Resonators (Student Paper) - D.-Y. Kim, D.-H. Cho, B.-H. Kim, J.-P. Jung, J.-S. Park and J.-B. Lee |
| P1U-B-1 | The Short-Pulse Subharmonic Response of Microbubbles Based on a Two-Frequency Approximation - C.-Y. Wu, M.-T. Lo, J. Tsao, D.-H. Tsai, Y.-C. Chang and D.-R. Su |
| P1U-B-2 | Using the Correlation Property of Subharmonic Response as an Index of Cavitation of Microbubbles - M.-T. Lo, J. Tsao and S. Lin |
| P1U-B-3 | Acoustical Characterization of Submicron Particles of Perfluorocarbon in Solution - O. Couture, E. Cherin and F. S. Foster |
| P1U-B-5 | An Acoustic Study of Disruption of Polymer-Shelled Bubbles - P. D. Bevan, R. Karshafian, M. Matsumura, G. Tickner and P. N. Burns |
| P1U-B-7 | In Vitro 40MHz Ultrasonic Characterisation of In-House Liposomal Dispersions Developed for Targeting Atherosclerotic Plaque - C. M. Moran, J. Ross, C. Cunningham, M. Butler and W. N. McDicken |
| P1U-C-1 | A High Voltage Pulser ASIC for Driving High Frequency Ultrasonic Arrays - G. I. Athanasopoulos, S. J. Carey and J. V. Hatfield |
| P1U-C-2 | Parallel Beamforming Using Synthetic Transmit Beams - T. Hergum, T. Bjåstad and H. Torp |
| P1U-C-3 | Algorithms of Three-Dimensional Beam Forming for Synthetic Aperture Imaging System Using Pulses Coded with Walsh Functions - K. Satoh, M. Miura, Y. Tamura, H. Yanagida, T. Yamasaki, C. Ishihara and N. Okada |
| P1U-C-4 | High Volume Rate 3-D Ultrasound Imaging Using Cross Array Based on Synthetic Transmit Focusing - K.-S. Kim and T.-K. Song |
| P1U-C-5 | Development of a Linear Power Amplifier for High Frame Rate Imaging System - J.-y. Lu and J. L. Waugaman |
| P1U-C-6 | High Frame Rate Imaging Using Parallel Transmission of Focused Coded Fields - T. Misaridis and P. Munk |
| P1U-C-7 | An Efficient 3D Beamformer Implementation for Real-Time 4D Ultrasound Systems Deploying Planar Array Probes - A. C. Dhanantwari, S. Stergiopoulos, L. Song, C. Parodi, F. Bertora, P. Pellegretti and A. Questa |
| P1U-C-8 | Synthetic Aperture Technique for Echographic Focusing Based on Pulse Compression - E. Biagi, L. Masotti, I. Rossi and M. Scabia |
| P1U-D-1 | Independent Component Analysis Based Source Separation in Physiological Strain Waves - L. Huang, J. C. Kucewicz and K. W. Beach |
| P1U-D-2 | Estimation of Time of Flight for Ultrasonic Reflex-Transmission Tomography with Active Contour Models - M. Ashfaq, M. P. Mienkina and H. Ermert |
| P1U-D-3 | A Study of Morphological Edge Enhancement by Double Structuring Element for Ultrasound B-Mode Images - M. Tsubai, T. Nishimura, A. Sasaki, T. Mitake and S.-i. Umemura |
| P1U-D-4 | Real-Time Respiration Phase Monitoring System Using Ultrasonic Bi-Plane Imaging Data for Proton Beam Therapy - T. Mochzuki, M. Kunita, Y. Toyama, A. Maruhashi and S. Murayama |
| P1U-D-5 | Development of a Dual-Gate Automatic Embolus Detection System - L. Fan, E. Boni, P. Tortoli and D. H. Evans |
| P1U-D-6 | Emboli Characterization in Blood Mimicking Fluid Circulation Using Parametric Modeling - M. Biard, J.-M. Girault, D. Kouamé and F. Patat |
| P1U-D-7 | Adaptive Noise Reduction Process Based on Gray-Level Concentrative Filter for CW Doppler Spectrogram - A. Sasaki, T. Azuma, H. Kamada, T. Hayashi, T. Nishimura and S. Umemura |
| P1U-D-8 | Detection and Analysis of Fetal Movements by Ultrasonic Multi-Sensor Doppler (ACTIFOETUS) - A. Kribèche, S. Benderbous, F. Tranquart, D. Kouamé and L. Pourcelot |
| P1U-E-1 | Correlation Between Acoustic Backscatter Variability and Tissue Damage Produced by Pulsed Cavitational Ultrasound Therapy - B. C. Tran, J. B. Fowlkes and C. A. Cain |
| P1U-E-2 | Resonance Frequency of Microbubbles in Small Blood Vessels - E. Sassaroli and K. Hynynen |
| P1U-E-3 | Involvement of Cavitation in the Appearance of Hyperechoic Regions in Ultrasound Image Visualization of High Intensity Focused Ultrasound Therapy: In-Vivo Results - B. A. Rabkin, V. Zderic and S. Vaezy |
| P1U-E-4 | Micro-Capsule Destruction Using Ultrasound for Drug Delivery System - D. Koyama, W. Kiyan and Y. Watanabe |
| P1U-E-6 | Ex-Vivo Study of Cavitation-Enhanced Heating by Combining Low (40 kHz) and High (566 kHz) Frequency Ultrasound - H.-L. Liu, T.-C. Shih, W.-S. Chen and B.-Y. Lu |
| P1U-E-7 | A Gel Phantom for the Calibration of MR-Guided Ultrasound Thermal Therapy - S. Lochhead, D. Bradwell, R. Chopra and M. J. Bronskill |
| P1U-F-1 | Diagnostic Results for Breast Disease by Real-Time Elasticity Imaging System - T. Matsumura, S. Tamano, R. Shinomura, T. Mitake, M. Yamakawa, T. Shiina, A. Itoh and E. Ueno |
| P1U-F-2 | Hardware Implementation for Receive Beamforming and Transverse Elasticity Imaging - P. Delachartre, H. Liebgott, S. Michelet, M. Pernot and D. Vray |
| P1U-F-3 | Signal Processing for Ultrasound-Based Arterial Pulse Wave Velocity Estimation - R. T. Hoctor, A. M. Dentinger and K. E. Thomenius |
| P1U-F-4 | Non-Invasive Vascular Elastography Based on a New 2-D Strain Estimator: Simulation and In Vitro Results - C. Schmitt, R. L. Maurice, J.-L. Gennisson and G. Cloutier |
| P1U-F-5 | Tissue Mimicking Phantom for Ultrasonic Elastography with Finely Adjustable Elastic and Echographic Properties - K.-i. Kawabata, Y. Waki, T. Matsumura and S.-i. Umemura |
| P1U-F-6 | Imaging of Cross-Sectional Elasticity in Short-Axis Plane of Arterial Wall by Transcutaneous Ultrasound - N. Nakagawa, H. Hasegawa and H. Kanai |
| P1U-F-7 | Nonlinearity Studies in Soft Tissues with the Supersonic Shear Imaging System - S. Catheline, J. Bercoff, J. L. Gennisson, C. Barrière and M. Fink |
| P1U-F-8 | The Effects of Fracture and Fracture Repair on the Vibrational Characteristics of an Excised Rat Femur - A. Alizad, M. Walch, J. F. Greenleaf and M. Fatemi |
| P1U-F-9 | Computational Aspects of Young's Modulus Reconstruction from Ultrasonic Freehand Scanning - J. Jiang and T. J. Hall |
| P1U-G-1 | SAW Antenna Duplexer for Trunking Communication - J. Liu, S. He and Y. Liang |
| P1U-G-2 | On the Design of an FBAR PCS Duplexer in LTCC Chip-Sized Package - F. M. Pitschi, J. E. Kiwitt, B. Bader and K. C. Wagner |
| P1U-G-3 | Optimized Test PCBs for SAW/FBAR RF Filters - H. Bilzer, F. M. Pitschi, J. E. Kiwitt, K. C. Wagner and W. Menzel |
| P1U-G-4 | Analysis of Parasitic Effects of GHz-Range SAW Matched Filters for Wireless Pulse Communication Systems - T. Sato, T. Sugiura and H. Nagasaka |
| P1U-G-6 | A Statistical Model of Passive Remote SAW Sensing Employing Differential Phase Measurement - Y. Shmaliy, O. Ibarra-Manzano and R. Rojas-Laguna |
| P1U-G-7 | Simulation of Wirelessly Passive SAW ID-Tags/Sensors Using VHDL-AMS - Q. Fu, W.-J. Fischer and H. Stab |
| P1U-H-1 | The Characteristics of Leaky Surface Acoustic Wave of Proton-Exchanged Lithium Tantalite - C.-J. Chung, Y.-C. Chen, C.-L. Wei, K.-S. Kao and C.-C. Cheng |
| P1U-H-2 | Quasi-Longitudinal Pseudo-Surface Acoustic Waves on Lithium Tantalate - V. I. Cherednick, M. Y. Dvoesherstov and K. Bhattacharjee |
| P1U-H-3 | Plate and Gap Acoustic Waves for Highly Sensitive Gas and Liquid Sensors - M. Y. Dvoesherstov, V. I. Cherednick and K. Bhattacharjee |
| P1U-H-4 | Roundtrips of SAW Along Multiple Routes on a Single Crystal LiNbO3 Ball - S. Akao, N. Nakaso, T. Ohgi and K. Yamanaka |
| P1U-H-5 | Transverse Acoustic Anisotropy of Obliquely Propagating LSAW in Resonator Structures on LiTaO3 and LiNbO3 Substrates - N. Naumenko and B. Abbott |
| P1U-H-6 | SAW Propagation in the Two Domain States of Ferroelectric LiNbO3 Crystal - J. Nosek |
| P1U-H-7 | Influence of Thin Conducting Layer on Leaky SH-SAW in Piezoelectric Crystal - B. D. Zaitsev, I. E. Kuznetsova and A. A. Teplykh |
| P1U-K-1 | Layered Cylindrical Viscosity Sensors - P. Kielczynski, W. Pajewski and M. Szalewski |
| P1U-K-3 | Pulsed Interrogation of the SAW Torque Sensor for Electrical Power Assisted Steering - V. Kalinin, G. Bown, J. Beckley and R. Lohr |
| P1U-K-4 | Thin Film Bulk Acoustic Wave Resonator (TFBAR) Gas Sensor - M. Benetti, D. Cannatà, A. D'Amico, F. Di Pietrantonio, V. Foglietti and E. Verona |
| P1U-K-5 | Ultrasonic Attenuation Acoustic Touch Panels - M. Takeuchi, T. Gotsu, N. Fujita, P. Gomes, J. Kent and R. Adler |
| P1U-K-6 | Measurement of Draught Using Ultrasonic Air Transducers - G. P. P. Gunarathne |
| P1U-K-7 | Reciprocity Calibration of Hydrophones in the Megahertz Frequency Range - C. Labuda, J. L. Raymond and C. C. Church |
| P1U-K-8 | A Localized Acoustic Field Formed in the Vicinity of a Bending-Vibrator End and its Application to Piezoelectric Sensors - K. Yamada, D. Yamazaki and K. Nakamura |
| P1U-K-9 | Clamp-On Shear Transducers Simplify Torsional and Extensional Investigations - L. C. Lynnworth, R. Cohen and T. H. Nguyen |
| P1U-L-1 | Second-Harmonic Generation of Lamb Waves in a Solid Layer on a Half Space - M. Deng, P. Wang and X. Lv |
| P1U-L-2 | Principles of Ultrasonic Velocimetry by Means of Nonlinear Interaction of Phase Conjugate Waves - Y. Pyl'nov, V. Preobrazhensky, O. Bou Matar and P. Pernod |
| P1U-L-3 | Numerical Analysis of Nonlinear Axisymmetrical Acoustic Resonators - C. Vanhille and C. Campos-Pozuelo |
| P1U-L-4 | Non Periodic Acoustic Devices Radiating in Semi-Infinite Solids Simulated by a Combination of Finite Element Analysis and a Boundary Element Method - M. Wilm, S. Ballandras and V. Laude |
| P1U-L-5 | Transient Cavitation Induced by Periodic Sequence of Tone Bursts - V. Andreev and V. Aleynikov |
| P1U-L-6 | 2D Numerical Simulation of Supercritical Phase Conjugation of Ultrasound in Active Solid - O. Bou Matar, V. Preobrazhensky and P. Pernod |
| P1U-L-7 | Combination Effect of Stacks as a Heat Pump on the Thermoacoustic Cooling System - S. Sakamoto, T. Tsujimoto and Y. Watanabe |
| P1U-L-8 | Basic Study on Effects of Acoustic Intensity and Sound Pressure on Surface Modification and Dispersion of Diamond Particles - T. Uchida, A. Hamano, N. Kawash |