Reflection of Ultrasonic Lamb Waves Produced by Thin Conducting Strips

Boris D. Zaitsev, and Shrinivas G. Joshi

The reflection of ultrasonic Lamb waves produced by a periodic array of thin conducting strips deposited on a piezoelectric plate was investigated both theoretically and experimentally. A repetitively mismatched transmission line model was used to analyze the performance of the reflector. The reflection coefficient of a single strip is given by R~ Δ v/v, where Δ v/v is the fractional change in velocity produced by electrical shorting of the propagation surface. An attractive property of Lamb waves is that they can provide a much higher value of Δ v/v than is possible with surface acoustic waves. Therefore, efficient Lamb wave reflectors can be realized with relatively few strips in the reflector. For example, reflection coefficient very close to unity, R~ 0.98, has been obtained in a Lamb wave reflector consisting of just 12 strips on a Y-X lithium niobate plate. The reflector has been used to realize a unidirectional transducer (UDT). A Lamb wave delay line consisting of two UDTs shows insertion loss of less than 3 dB with fractional bandwidth greater than 7%.

© 1999, by The Institute of Electrical and Electronics Engineers, Inc. All rights reserved.