Alf Püttmer, Peter Hauptmann, Ralf Lucklum, Olaf Krause, and Bernd Henning
ABSTRACT
A transmission line equivalent circuit for piezoelectric transducers has been modified to provide modeling of lossy piezoceramic transducers. A lossy transmission line is used to model the mechanical losses. The equivalent circuit parameters are derived from analogies between electrical transmission lines and acoustic wave propagation. Implementation of the equivalent circuit model in SPICE is shown. Simulations and measurements in the time and frequency domain of a low-Q material and a multilayered ultrasonic sensor using a low-Q piezoceramic transducer are presented.1997 IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 44:60-66