ABSTRACT The magnetic sensitivity of quartz crystal resonators is a consequence of the ferromagnetic properties of the metal used as support for the vibrating plate. Various magneto-mechanic interactions can contribute to the overall sensitivity, the most important of which is shown to be the change in Young's modulus of the spring material submitted to a magnetic field, which in turn modifies the stress in the quartz plate and then induces a change in the crystal resonant frequency. The experimental setup and procedure are described and a large number of experimental results obtained with resonators of different technologies are presented and discussed. A comparison between the magnetic behavior of identical resonators mounted with different materials definitely proves the responsibility of the supports in the magnetic sensitivity of resonators and gives interesting information on its reduction.
© 1996, by The Institute of Electrical and Electronics Engineers, Inc. All rights reserved.