Electroacoustic Model for Electrostatic Ultrasonic Transducers with V-Grooved Backplates

Pentti Mattila, Fabio Tsuzuki, Heli Väätäjä, and Ken Sasaki

ABSTRACT Capacitive ultrasonic transducers are widely used to generate airborne ultrasound. This paper presents an equivalent circuit for an electrostatic transducer with a V-grooved backplate. The comparison between simulation results and measurements on a prototype transducer shows that the model gives reliable results. This model is useful in many applications, for example to simulate sensors in a robot and to design ultrasonic transducer systems.

© 1995, by The Institute of Electrical and Electronics Engineers, Inc. All rights reserved.