A Noncontact Method for Detecting Acoustic Emission Using a Microwave Doppler Radar Motion Detector

Gregory C. Smith

ABSTRACT A noncontact method for detecting acoustic emission was developed, using a microwave Doppler radar detector and an active band-pass filter. A theoretical model was developed and a prototype sensor was built and tested. The prototype responds to acoustic emissions (AE), from pencil lead break tests, at ranges up to 1.5 feet.

© 2005, by The Institute of Electrical and Electronics Engineers, Inc. All rights reserved.