Quantitative Imaging of Rayleigh Wave Velocity with a Scanning Acoustic Microscope

Shamachary Sathish and Richard W. Martin

ABSTRACT An acoustic microscope operating with impulse excitation has been used to perform measurements of the Rayleigh wave velocity by measuring the time difference between the direct reflected signal and the Rayleigh wave signal. The accuracy and precision of the methodology have been examined by performing measurements at a single location on an elastically isotropic sample of E6 glass. The accuracy of the Rayleigh wave velocity measurement has been determined to be better than 0.5%. The measured Rayleigh wave velocity of (3035 ± 5) m/s differs by 0.3% from measurements reported in the literature for a similar sample, using two different techniques. The methodology has been extended to acquire the Rayleigh wave velocity while raster scanning the sample to develop a quantitative velocity image. The background noise in the Rayleigh wave velocity image has been investigated by mapping the velocity on elastically isotropic E6 glass. Possible reasons for background noise in the images is discussed. The methodology has been extended to acquire quantitative Rayleigh wave velocity images on Ti-6Al-4V. The contrast in the images is attributed to the variation of the Rayleigh wave velocity in individual grains or regions. Applicability of the technique to investigate crystallographic texture in materials is discussed.

© 2002, by The Institute of Electrical and Electronics Engineers, Inc. All rights reserved.